27
www.leantechnik.com
14 Malfunctions
14 Malfunctions
Leantechnik accepts no liability or warranty for the use of spare parts and accessories not supplied by Leantechnik,
or for any resulting damage.
Error
Possible causes
Correction
Execution
Brake does not ventilate
Brake does not brake
Brake does not release
Braking distance too long
Switching condition monitor-
ing gives no signal
Operating pressure too low
Valve faulty
Leak in the supply line
Wear limit of the brake
reached
Valve faulty
Profile rail does not fit
the brake
Cross section of supply line
too small
Profile rail does not fit the
brake
Profile rail / brake shoes
worn too much
Cross section of lines too
small
Friction-reducing substances
on the profile rail
Incorrect dimensioning
3/2-way valve too slow
Mounting and adjustment
of the switching condition
monitoring faulty
Brake does not ventilate
Cable faulty
Proximity switch faulty
Check the operating pressure
and increase if necessary
Replace the faulty valve
Seal the leak
Replace the brake
Replace the faulty valve
Check the design, check
technical data
Attach a line with a
larger cross-section
Check the design, check
technical data
Replace the faulty cable
Attach line with a larger
cross section
Clean the profile rail
Check the design, check
technical data
Carry out the setting again,
see 9.1
See error Brake
does not ventilate
Replace the brake
Replace the faulty proximity
switch
Qualified
personnel
Leantechnik AG
Qualified
personnel
Qualified
personnel
Leantechnik AG
i