Robotiq Hand-E Gripper Instruction Manual
Step 2: Read Gripper status until the activation is completed
Request is: 09 03 07 D0 00 01 85 CF
Bits
Description
09
SlaveID
03
Function Code 03 (Read Holding Registers)
07D0
Address of the first requested register
0001
Number of registers requested (1)
85CF
Cyclic Redundancy Check (CRC)
Response (if the activation ISNOT completed): 09 03 02 11 00 55 D5
Bits
Description
09
SlaveID
03
Function Code 03 (Read Holding Registers)
02
Number of data bytes to follow (1 register x 2 bytes/ register = 2 bytes)
1100
Content of register 07D0 (GRIPPER STATUS= 0x11, RESERVED = 0x00): gACT = 1 for " Gripper Activation", gSTA = 1 for
"Activation in progress"
55D
5
Cyclic Redundancy Check (CRC)
Response (if the activation IScompleted): 09 03 02 31 00 4C 15
Bits
Description
09
SlaveID
03
Function Code 03 (Read Holding Registers)
02
Number of data bytes to follow (1 register x 2 bytes/ register = 2 bytes)
3100
Content of register 07D0 (GRIPPER STATUS= 0x31, RESERVED = 0x00): gACT = 1 for " Gripper Activation", gSTA = 3 for
"Activation is completed"
4C15
Cyclic Redundancy Check (CRC)
51
Содержание ROBOTIQ HAND-E
Страница 19: ...Robotiq Hand E Gripper Instruction Manual Fig 3 2 Mounting fingertips on holders and then on the racks 19...
Страница 25: ...Robotiq Hand E Gripper Instruction Manual Fig 3 6 RS 485 to USB converter ACC ADT USB RS485 pinout 25...
Страница 30: ...Robotiq Hand E Gripper Instruction Manual Fig 4 1 Hand E control logic overview 30...
Страница 85: ...9 Troubleshooting Section to be populated soon Robotiq Hand E Gripper Instruction Manual 85...
Страница 90: ...Robotiq Hand E Gripper Instruction Manual 1 2 3 IngressProtection Certificate 90...