background image

Leaf LT88 / LT88E manual 

 

Page  22  Of  22 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the 
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures: 

 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

Modifications not expressly approved by the manufacturer could void the user's authority to operated the equipment under FCC 
rules. 

 

 

LTB1 & LTB1E: BREAKOUT  

 

FEATURE 

SPECIFICATION 

INPUTS: MAIN A/V 

(1x) HDBase-T Input 

. See LT88 for further specificaiotn.

 

OUTPUTS: AUDIO/VIDEO 

(1x) HDMI output  

INPUT: AUDIO 

(1X) Digital coax (S/PDIF)  via RCA socket 

Audio return from RCA socket specification: 
Range: 50 metres or is subjected to electrical 
interference, cable type, power supplies used  etc.

 

OUTPUTS: ETHERNET  
(LTB1E only) 

(1x) ETHERNET OUTPUT 

OUTPUTS:RS232 

(1x) RS-232 PORT (BLACK RJ45 CONNECTOR) Up to 115200 
Baud. 

OUTPUT: IR THROUGHPUT 

IR LED DRIVER 38KHz...  OR...  IR INPUT. (Selected by main 
unit). 3.5mm TRS female connector  

NUMBER OF INPUTS/OUTPUT 

1/1 

POWER 

Local power required 12W (1A @ 12V).  

DIMENSIONS (W,D,H) 

116mmx121mmx31mm(36mm with wall plate fitted) 

LT88E

 

Содержание Leaf True LT88

Страница 1: ...8 X 8 Video Matrix Systems LT88 LT88E...

Страница 2: ...tion please switch off and unplug mains power from this system and any equipment that is to be connected to it prior to connecting any leads cables Plug in and switch power back on again after all int...

Страница 3: ...1 Single LT88 E use 10 3 8 2 Multiple LT88 E use 10 3 9 Bank Select Switch 11 3 10 RS232 Termination TERM Switch 11 3 11 HDMI Input ports 11 4 BREAKOUTS 12 4 1 Local Power 12 4 2 Mounting Bracket 12...

Страница 4: ...ures the LT88E extends this by providing Ethernet through feed capability The LT88E has additional circuitry and dedicated RJ45 type ports on its front panel that connect to matching Ethernet ports at...

Страница 5: ...e metal housings and are provided with rubber feet should table desktop mounting be preferred 2 Front Panel Layout The LT88 and LT88E front panels are fitted with connectors visual indicators and cont...

Страница 6: ...Ethernet ports indicate handshake between the LT88E and host Ethernet devices to which it is connected but does not necessarily indicate data flow from end to end 2 3 Front Panel LED display and selec...

Страница 7: ...ype Leaf Control input port 2 1 x 4 way Dip Switch module 3 8 x RCA S PDIF digital coax audio input sockets 4 8 x pairs of RCA line level stereo output sockets 5 8 x 3 5mm Tip Ring Sleeve sockets for...

Страница 8: ...N with a stereo tip ring sleeve plug at the Leaf end with the ring floating not connected or with the ring connected to tip 3 Normal Mode Compatibility Mode 4 Future Function Future Function Table 1 D...

Страница 9: ...r similar instead of stand alone IR detectors For this configuration Stereo Tip Ring Sleeve 3 5mm leads must be used instead of Mono leads for the IR interconnections from the control system to the Le...

Страница 10: ...th a straight through DB9 Male to Female RS232 lead Some control systems may require only the TxD RxD and Gnd wires of an RS232 lead to be connected The pin configurations of these 3 connections on th...

Страница 11: ...8h to 3Fh 8 65 to 72 64 to 71 40h to 47h 9 73 to 80 72 to 79 48h to 4Fh A 81 to 88 80 to 87 50h to 57h B 89 to 96 88 to 95 58h to 5Fh C 97 to 104 96 to 103 60h to67h D 105 to 112 104 to 111 68h to 6Fh...

Страница 12: ...45 type socket for Ethernet throughput and is designed to match the capabilities of the LT88E 4 1 Local Power Each breakout LTB1 LTB1E is required to be powered by its own local power supply and to be...

Страница 13: ...active LED 2 ON The HDBaseT Cat5e Cat6 cable link to the LT88 E has been made successfully and is ready for video LED 3 ON Protected HDCP video content is being transferred on the HDBaseT link FLASHIN...

Страница 14: ...ive Source Selection Zone Lock mode A source can be locked to a particular zone The exclusive source selection feature enables enhanced features such as multichannel audio 3D etc to become active in t...

Страница 15: ...t connectors on the LT88 LT88E The source range for the selected audio inputs under this feature becomes HDMI input ports 1 to 8 LTB1 LTB1E Breakouts 9 to 16 LT88 LT88E 17 to 24 This feature is activa...

Страница 16: ...dicated by the upper left hand LED only pulsing green blue 6 2 Calibration The system should be calibrated on first use or after any new devices source or zone equipment are added or port allocations...

Страница 17: ...ng these steps in sequence Manually select output zone Press the right hand press button switch sequentially until the LED in the lower row corresponding to the desired output zone is blue then releas...

Страница 18: ...second step above the left hand press button switch is pressed until no Blue LEDs are displayed in the upper row the connection will be cleared i e the output will be disconnected from the input 6 4...

Страница 19: ...f LT88 LT88E manual Page 19 Of 22 7 Interconnections 7 1 Possible interconnections at front panel LT88E depicted LT88 is similar but without the Ethernet ports 7 2 Possible interconnections at rear pa...

Страница 20: ...Leaf LT88 LT88E manual Page 20 Of 22 7 3 Possible interconnections at LTB1E LTB1 is similar but without the Ethernet port...

Страница 21: ...rol 1x RS232 DB9 IN 1x RS232 DB9 LOOPOUT Bank select and termination selectors 6 INFRA RED REMOTE CONTROL THROUGHPUT ONLY No direct control by IR 8x DIRECTIONAL IR INPUTs Support for Direct IR IR TX B...

Страница 22: ...ncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced...