background image

Leaf LT88 / LT88E manual 

 

Page  10  Of  22 

 

 

3.7  4 pin DIN power connector 

The LT88/E requires 4 Pin 12V power.  

WARNING. Failure to use the correct power supply as provided by Leaf Audio 
may result in incorrect operation and / or damage to the Leaf True Matrix system.  

 

 

 

 

 

 

 

 

 

The power supply is fitted with a locking connector. Be sure to slide back the 
locking sleeve on the plug before attempting to connect or disconnect it at the 
LT88/E. The correct connector orientation for these models is 

“Flat Side down”. 

3.8  RS232 Serial Control connectors 

 

The unit can be controlled by serial commands through the RS232 input port. Typically 
this  would  be  connected  to  a  control  system  with  a  straight  through  DB9  Male  to 
Female  RS232  lead.  Some  control  systems  may  require  only  the  TxD,  RxD  and  Gnd 
wires of an RS232 lead to be connected. The pin configurations of these 3 connections 
on the DB9 plug is: TxD = Pin 2, RxD = Pin3, Gnd = Pin5. 

 

3.8.1  Single LT88/E use  

  The RS232 Input port is used for controlling the unit. 

  The TERM (Termination) switch (ref: para 3.10) must be set to ON (Up). 

3.8.2  Multiple LT88/E use  

  Multiple units can be chained together and addressed on the same RS232 link 

by connecting the RS232 thru (out) port on one unit to the RS232 input port of 
the next unit.  

The last unit in the chain must have the TERM (Termination) switch (ref:para 3.10) 
set to ON (Up), while all other units in the chain must have this switch set to OFF 
(Down). The RS232 Input port is used for controlling the units. 

Spring loaded 
locking sleeve 

Slide back to 
release 

Flat side 

Содержание Leaf True LT88

Страница 1: ...8 X 8 Video Matrix Systems LT88 LT88E...

Страница 2: ...tion please switch off and unplug mains power from this system and any equipment that is to be connected to it prior to connecting any leads cables Plug in and switch power back on again after all int...

Страница 3: ...1 Single LT88 E use 10 3 8 2 Multiple LT88 E use 10 3 9 Bank Select Switch 11 3 10 RS232 Termination TERM Switch 11 3 11 HDMI Input ports 11 4 BREAKOUTS 12 4 1 Local Power 12 4 2 Mounting Bracket 12...

Страница 4: ...ures the LT88E extends this by providing Ethernet through feed capability The LT88E has additional circuitry and dedicated RJ45 type ports on its front panel that connect to matching Ethernet ports at...

Страница 5: ...e metal housings and are provided with rubber feet should table desktop mounting be preferred 2 Front Panel Layout The LT88 and LT88E front panels are fitted with connectors visual indicators and cont...

Страница 6: ...Ethernet ports indicate handshake between the LT88E and host Ethernet devices to which it is connected but does not necessarily indicate data flow from end to end 2 3 Front Panel LED display and selec...

Страница 7: ...ype Leaf Control input port 2 1 x 4 way Dip Switch module 3 8 x RCA S PDIF digital coax audio input sockets 4 8 x pairs of RCA line level stereo output sockets 5 8 x 3 5mm Tip Ring Sleeve sockets for...

Страница 8: ...N with a stereo tip ring sleeve plug at the Leaf end with the ring floating not connected or with the ring connected to tip 3 Normal Mode Compatibility Mode 4 Future Function Future Function Table 1 D...

Страница 9: ...r similar instead of stand alone IR detectors For this configuration Stereo Tip Ring Sleeve 3 5mm leads must be used instead of Mono leads for the IR interconnections from the control system to the Le...

Страница 10: ...th a straight through DB9 Male to Female RS232 lead Some control systems may require only the TxD RxD and Gnd wires of an RS232 lead to be connected The pin configurations of these 3 connections on th...

Страница 11: ...8h to 3Fh 8 65 to 72 64 to 71 40h to 47h 9 73 to 80 72 to 79 48h to 4Fh A 81 to 88 80 to 87 50h to 57h B 89 to 96 88 to 95 58h to 5Fh C 97 to 104 96 to 103 60h to67h D 105 to 112 104 to 111 68h to 6Fh...

Страница 12: ...45 type socket for Ethernet throughput and is designed to match the capabilities of the LT88E 4 1 Local Power Each breakout LTB1 LTB1E is required to be powered by its own local power supply and to be...

Страница 13: ...active LED 2 ON The HDBaseT Cat5e Cat6 cable link to the LT88 E has been made successfully and is ready for video LED 3 ON Protected HDCP video content is being transferred on the HDBaseT link FLASHIN...

Страница 14: ...ive Source Selection Zone Lock mode A source can be locked to a particular zone The exclusive source selection feature enables enhanced features such as multichannel audio 3D etc to become active in t...

Страница 15: ...t connectors on the LT88 LT88E The source range for the selected audio inputs under this feature becomes HDMI input ports 1 to 8 LTB1 LTB1E Breakouts 9 to 16 LT88 LT88E 17 to 24 This feature is activa...

Страница 16: ...dicated by the upper left hand LED only pulsing green blue 6 2 Calibration The system should be calibrated on first use or after any new devices source or zone equipment are added or port allocations...

Страница 17: ...ng these steps in sequence Manually select output zone Press the right hand press button switch sequentially until the LED in the lower row corresponding to the desired output zone is blue then releas...

Страница 18: ...second step above the left hand press button switch is pressed until no Blue LEDs are displayed in the upper row the connection will be cleared i e the output will be disconnected from the input 6 4...

Страница 19: ...f LT88 LT88E manual Page 19 Of 22 7 Interconnections 7 1 Possible interconnections at front panel LT88E depicted LT88 is similar but without the Ethernet ports 7 2 Possible interconnections at rear pa...

Страница 20: ...Leaf LT88 LT88E manual Page 20 Of 22 7 3 Possible interconnections at LTB1E LTB1 is similar but without the Ethernet port...

Страница 21: ...rol 1x RS232 DB9 IN 1x RS232 DB9 LOOPOUT Bank select and termination selectors 6 INFRA RED REMOTE CONTROL THROUGHPUT ONLY No direct control by IR 8x DIRECTIONAL IR INPUTs Support for Direct IR IR TX B...

Страница 22: ...ncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced...

Отзывы: