CS3E-E Series EtherCAT Closed Loop stepper drive User Manual
53
speed value of 0x60C6, keep
operation enable state;
4: After stopping immediately, keep
operation enable state.
6060
00
Operation mode
R/W
USINT
0-255
8
--
1: PP mode,
3: PV mode,
6: Home mode,
8: CSP mode
6061
00
Operation
mode
display
R
USINT
0-255
8
--
-
6062
00
Position command
R
DINT
-2147483648
~2147483647
0
Pulse
-
6064
00
Position
actual
value
R
DINT
-2147483648
~2147483647
0
Pulse
-
6067
00
Distance to send "In
Position" output
signal
R/W/S
UINT
0-1000
4
Pulse
It is recommended to use this
object in preference, Can also set
by 0x2032,
606B
00
Velocity command
R
DINT
-2147483648
~2147483647
0
P/s
-
606C
00
Velocity
actual
value
R
DINT
-2147483648
-2147483647
0
P/S
-
607A
00
Target position
R/W
DINT
-2147483648
~2147483647
0
P
Target position under PP mode
607C
01
Home offset
R/W
DINT
-2147483648
~2147483647
0
P
The value of difference between
zero position and mechanical zero
point under Homing mode .
If the value is set to10000, it means
that at homing mode 19, the motor
reaches the Home switch and stops
immediately, then reverses at low
speed until it leaves the Home
switch, at last stops at a distance of
10000P.
607D
01
Software
negative
limit
R/W
DINT
-2147483648
~2147483647
0
P
New target positions are checked
against these limits. The limits are
relative to the machine home
position, which is the result of
homing. As default the software
position limits are switched off.
Changed values must be saved and
the drive must be restarted to take
enable the new the software limits.
607D
02
Software
positive
limit
R/W
DINT
-2147483648
~2147483647
0
P
607E
00
Motor direction
R/W
USINT
0~255
0
--
Need to set 0x225C first
60FF
00
Target velocity
R/W
DINT
-2147483648
~2147483647
0
P/S
Profile velocity under PV mode
6080
00
Max velocity limit
R/W/S
UDINT
-2147483648
~2147483647
3000
rpm
-
6081
00
Max profile velocity
R/W/S
DINT
-2147483648
~2147483647
50000
--
Max. Allowable velocity under PP
mode
6082
00
Start velocity
R/W/S
DINT
-2147483648
~2147483647
0
--
Start velocity under PP mode
6083
00
Profile acceleration
R/W/S
DINT
-2147483648
~2147483647
4000
P/S^2
Acceleration under PP and PV
mode
6084
00
Profile deceleration
R/W/S
DINT
-2147483648
~2147483647
4000
P/S^2
Deceleration under PP and PV
mode
6085
00
Quick
stop
deceleration
R/W/S
DINT
-2147483648
~2147483647
40000000
0
P/S^2
Deceleration of quick stop under PP,
PV and Home mode
608F
01
Encoder resolution
R/W/S
UINT
4000-20000
4000
Coun
t
It is recommended to use this
object in preference, can also set by
0x2029,