3DM580 Digital Stepping Driver Manual V1.1
Tel: +086 755-26434369
11
Web Site: www.leadshine.com
Over-voltage Protection
When power supply voltage exceeds 62
±
1 VDC, protection will be activated and RED LED will
turn on twice within each periodic time (3 s).
Short-Circuit Protection
Motor power lines wrong & not connected will activate this protection. RED LED will turn on
four times within each periodic time (3 s).
Attention:
When above protections are active, the motor shaft will be free or the LED will turn
red. Reset the driver by repowering it to make it function properly after removing above problems.
Since there is no protection against power leads (
﹢
,
﹣
) reversal, it is critical to make sure that
power supply leads correctly connected to driver. Otherwise, the driver will be damaged instantly.
Protection Indications
Priority
Time(s) of ON
Sequence wave of RED LED
Description
1
st
1
Over-current protection
2
nd
2
Over-voltage protection
3
rd
4
Short-circuit protection
12. Frequently Asked Questions
In the event that your driver doesn’t operate properly, the first step is to identify whether the
problem is electrical or mechanical in nature. The next step is to isolate the system component that
is causing the problem. As part of this process you may have to disconnect the individual
components that make up your system and verify that they operate independently. It is important to
document each step in the troubleshooting process. You may need this documentation to refer back
to at a later date, and these details will greatly assist our Technical Support staff in determining the
problem should you need assistance.
Many of the problems that affect motion control systems can be traced to electrical noise,
controller software errors, or mistake in wiring.