5. REMOTE CONTROL 

16

 

 

No. 21 

Command SCE 

Description 

Send the CEC data 

Notes 

Tx parameter 3 can be omitted. 
If transmission fails, Rsp. parameters 1 to 3 will not be returned. 

 

Data 

Description 

Format

00 to FF 

Transmission header 
The higher 4 bits are the LT 6280A address. 
The lower 4 bits are the HDMI source device address. 

HEX 

00 to FF 

CEC OP code 

HEX 

Tx parameter 

Up to 15 bytes 

CEC parameter 

HEX 

00 to FF 

Same as Tx parameter 1 

HEX 

00 to FF 

Same as Tx parameter 2 

HEX 

Rsp. parameter 

Up to 15 bytes 

Same as Tx parameter 3 

HEX 

 

No. 22 

Command RCE 

Description 

Get the received CEC data 

Notes 

If there is no received data, Rsp. parameters 1 to 3 will not be returned. 

 

Data 

Description 

Format

00 to FF 

Transmission header 
The higher 4 bits are the HDMI source device address. 
The lower 4 bits are the LT 6280A address. 

HEX 

00 to FF 

CEC OP code 

HEX 

Rsp. parameter 

Up to 15 bytes 

CEC parameter 

HEX 

 

No. 23 

Command NCE 

Description 

Get the number of received CEC data 

 

Data 

Description 

Format

Rsp. parameter 

0 to 16 

Number of received CEC data 

DEC 

 

No. 24 

Command LED 

Description 

Set the STATUS LED 

 

Data 

Description 

Format

00 (when omitted) 

STATUS 1: Off 

STATUS 2: Off 

HEX 

01 

STATUS 1: Off 

STATUS 2: Lit in red 

HEX 

02 

STATUS 1: Lit in green 

STATUS 2: Off 

HEX 

Tx parameter 
(can be omitted) 

03 

STATUS 1: Lit in green 

STATUS 2: Lit in red 

HEX 

Rsp. parameter 

00 to 03 

Same as the Tx parameters 

HEX 

Содержание LT 6280A

Страница 1: ...LT 6280A HDMI SOURCE DEVICE CHECKER INSTRUCTION MANUAL...

Страница 2: ...2 SPECIFICATIONS 2 2 1 Description 2 2 2 Features 2 2 3 Specifications 3 2 3 1 HDMI Input 3 2 3 2 External Interface 3 2 3 3 Features 3 2 3 4 General Specifications 4 3 PANEL DESCRIPTION 5 3 1 Front...

Страница 3: ...tand If you have any questions about the contents of this manual please contact your local LEADER agent Symbols and Terms The following symbols and terms are used in this instruction manual and on the...

Страница 4: ...that the instrument has condensation within it wait for approximately 30 minutes before turning on the power Operating Humidity Range Use this instrument in an environment whose relative humidity is...

Страница 5: ...er outlet do not pull on the cord Pull from the plug Warnings Concerning Grounding The instrument has a ground terminal to protect the user and the instrument from electric shock Ensure that the produ...

Страница 6: ...with mild detergent and wipe gently While cleaning make sure that foreign materials such as water and detergent do not enter the instrument If liquid or a metal object enters into the instrument fire...

Страница 7: ...een improperly repaired adjusted or modified by personnel other than a factory trained LEADER representative 3 Repair of malfunctions or damages resulting from improper use 4 Repair of malfunctions ca...

Страница 8: ...the comparison result and the number of mismatched data points or the mismatched data positions to a PC Audio Data Checking The LT 6280A can send the output level of the audio data that is being recei...

Страница 9: ...3 3 Features Video Data Checking Compares received video data with reference data Sends the comparison result and the number of mismatched data points or the mismatched data positions to a PC TMDS Inp...

Страница 10: ...on Optimal Temperature 10 to 35 C Operating Environment Indoors Elevation Up to 2 000 m Overvoltage Category II Pollution Degree 2 Power Requirements Voltage 90 to 250 VAC Frequency 50 60 Hz Power Con...

Страница 11: ...n be turned on and off remotely 3 POWER Lights when the power is on 3 2 Rear Panel No Name Description 1 Fan Cooling fan 2 Ground terminal Connect to an external ground 3 HDMI Connect to an HDMI sourc...

Страница 12: ...e operation of the HDMI source device For information on remote control see the next chapter 4 2 Turning the Power On When you turn on the LT 6280A the STATUS LED changes as shown below It takes 30 se...

Страница 13: ...1 Space Tx parameter 2 CR Response Messages The number of parameters varies depending on the response Some responses do not have any parameters If there is an error in a transmission command the LT 62...

Страница 14: ...image and saves it Response SIF test bmp 1280 720 8 Successful save operation Comparison Using the image data saved in Preparation as a reference compare images Send RID Retrieves the image to compare...

Страница 15: ...e HDCP authentication status 13 HEC Clear the number of HDCP errors 14 HAC Clear the number of HDCP authentication completions 15 RHD Get the HDCP data 16 RPT Set the HDCP operation mode 17 CRI Clear...

Страница 16: ...C Tx parameter can be omitted 1 1 Get Rsp parameters 1 to 13 DEC 1 0 1 Same as the Tx parameters DEC 2 0 to 1920 Image data width DEC 3 0 to 1470 Image data height DEC 0 Progressive DEC 4 1 Interlace...

Страница 17: ...essary Data Description Format 0 when omitted Left image DEC Tx parameter can be omitted 1 1 Right image DEC 1 0 or 1 Same as the Tx parameters DEC 2 0 to 1920 Image data width DEC 3 0 to 1080 Image d...

Страница 18: ...o 12 Number of color bits in the image data DEC No 7 Command CMP Description Compare the image data Notes Compares the image data retrieved using RID and that loaded using LIF For example addresses wh...

Страница 19: ...ter 12 0 to 65535 Channel 5 minimum level DEC No 9 Command APP Description Get the audio amplitude level Notes Retrieves the maximum and minimum amplitude levels over the last 200 ms For stereo input...

Страница 20: ...5 other DEC 6 GBD DEC Tx parameter can be omitted 1 7 VSI DEC 1 0 to 7 Same as the Tx parameters DEC Rsp parameter 2 Up to 32 bytes InfoFrame data HEX No 12 Command HDS Description Get the HDCP authen...

Страница 21: ...Format 0 when omitted Sink mode DEC Tx parameter can be omitted 1 1 Repeater mode DEC Rsp parameter 1 0 or 1 Same as the Tx parameters DEC No 17 Command CRI Description Clear the HDCP Ri No 18 Comman...

Страница 22: ...Notes If there is no received data Rsp parameters 1 to 3 will not be returned Data Description Format 1 00 to FF Transmission header The higher 4 bits are the HDMI source device address The lower 4 bi...

Страница 23: ...parameter can be omitted 4 Gateway STR 1 0 or 1 Same as Tx parameter 1 DEC 2 Same as Tx parameter 2 STR 3 Same as Tx parameter 3 STR Rsp parameter 4 Same as Tx parameter 4 STR No 27 Command INT Descr...

Страница 24: ...9 Command VER Description Get the version information Data Description Format 1 00000000 to 99999999 Application version DEC 2 00000000 to 99999999 Sub microprocessor version DEC Rsp parameter 3 0000...

Страница 25: ...eness accuracy and effectiveness of it About the Sample Software Application If you run LT6280A_Remote_Sample exe the following screen will appear You can use the screen to remotely control the LT 628...

Страница 26: ...Following information is for Chinese RoHS only LT 6280A 2006 2 28 SJ T11364 2006 Hazardous Substances in each Part Parts Pb Hg Cd Cr PBB PBDE SJ T11363 2006 SJ T11363 2006 Ver 1...

Страница 27: ...LEADER ELECTRONICS CORP 2 6 33 Tsunashima Higashi Kohoku ku Yokohama 223 8505 Japan PHONE 81 45 541 2123 FAX 81 45 541 2823 http www leader co jp May 11 2012 Ver 1 FW Ver 3 0...

Отзывы: