04 MAINTENANCE AND SERVICE
Before any maintenance is necessary to carefully read all
SAFETY INFORMATION 01!
Damages caused by inadequate cleaning or maintenance are not covered by warranty.
Requires periodic cleaning (dust, dirt ,...)
Procedure for maintenance:
Unplug mains before maintenance and at least 10 minutes cool off.
Appliance do not illegal open or demount. Clean-up dust only from outer surface.
Use vacuum or dumpy duster (warm water)
Before reinstalling make sure everything is intact and dry– no wet parts!
Service:
Customer service provided by the manufacturer.
-
-
-
-
-
-
-
90V
~
264V
IP20
90°
1. Mechanical mounting of LL HBDW DS21-NA-I20
1
2
Make the power and DMX connection.
3
WARNING!!!
Installation can be done only by a qualifi ed professional in accordance
with relevant local codes.
LL HIGH BAY DOWNLIGHT
Weight
LL HBDW DS21-NA-I20-16-50W-056-45K-C80
4,10 kg
9lbs
LL HBDW DS21-NA-I20-24-75W-056-45K-C80
4,10 kg
9lbs
LL HBDW DS21-NA-I20-25-75W-056-45K-C80
4,10 kg
9lbs
LL HBDW DS21-NA-I20-36-100W-056-45K-C80
4,40 kg
9,7lbs
BASIC RANGE
!
Ø 13mm
03.4 Control data connection
Control data cable length is specifi ed by Norm IEC929 Annex E4.
It is not necessary to open the fi xture before connecting of DMX512 control
signal. Interconnections are realized by Neutrik XLR 5pin In/Out connectors.
Pin connections:
Pin 1 – ground
Pin 2 – signal negative
Pin 3 – signal positive
-
-
-
03.5 DMX channels
These informations are subject to change. Look for the latest products DMX
personality on: www.leaderlight.eu
90-264V AC 47-63Hz In
PowerCon