WSE EVAPORATOR MANUAL
WSE Operations Manual
Year: 2018
PAGE: 26
12.
If tape was used to hold the pan gasket, remove it now.
8.
Place the 4” X 24” pan gasket between the pans. It
should be centered so the ends overlap the rails. If
necessary, use a small piece of tape to hold the
gasket in place.
9.
Place the syrup pan on the arch so one welded
ferrule is in the rear on the side opposite the float
box. A left draw pan has the rear ferrule on the
right. A right draw pan has the ferrule on the left.
10.
Move the syrup pan toward the flue pan:
a.
Slide the float box brace into the bracket on the
side of the syrup pan.
b.
Compress the pan gasket to hold it in place.
c.
Place the thumbscrew into the syrup pan
bracket and tighten the thumbscrew of the
syrup and flue pans.
11.
Install the U-tube
a.
Place a 1 ½” Teflon gasket onto the ferrule of
the flue pan to be connected to the U-tube
(same side as the rear ferrule on the syrup pan).
b.
Place the U-tube over the gasket. Align the
clamp so the bolt is inside the u-tube and the
wing nut faces down. Ensure the gasket aligns
with the grooves in the ferrules.
c.
Loosen the wing nut on a 1 ½” clamp and open
up the clamp. Place the clamp over the ferrules
and gasket. Close the clamp with the wing nut
and partially tighten.
d.
Place a 1 ½” Teflon gasket onto the rear ferrule
of the syrup pan to be connected to the U-Tube.
Place the U-tube over the gasket.
e.
Loosen the wing nut on a 1 ½” clamp and open
up the clamp. Place the clamp over the ferrules
and gasket. Align the clamp so the bolt is inside
the u-tube and the wing nut faces down. Close
the clamp with the wing nut and partially
tighten.
f.
Ensure the U-tube and pans are aligned then
fully tighten both clamps.