background image

4 Technical specifications

Part no.

0101033810

Part no.

0101033811

Part no.

0101033813

Modell

Champ 1217

Champ 1217

Champ 1217

Battery type

Lead (gel/AGM)

Lead (wet)

Lead (gel/AGM)

Battery capacity

55 Ah ... 170 Ah

55 Ah ... 170 Ah

55 Ah ... 170 Ah

Charging charac-
teristics

IU1U2 pre-pro-
grammed, cannot

be changed

IU1U2 pre-pro-
grammed, cannot

be changed

IU1U2 pre-pro-
grammed, cannot

be changed

Charging current

17 A

17 A

17 A

Ripple

< 3 %

< 3 %

< 3 %

Main charging

14.4 V

14.1 V

14.4 V

Trickle charging

13.8 V

13.5 V

13.8 V

Input voltage

230 V

230 V

230 V

Input values

190 V ... 270 V

190 V ... 270 V

190 V ... 270 V

Input frequency

40 Hz ... 60 Hz

40 Hz ... 60 Hz

40 Hz ... 60 Hz

Switching fre-
quency

100 kHz

100 kHz

100 kHz

Degree of effi-
ciency, max.

> 88 %

> 88 %

> 88 %

Quiescent current
(from the battery)

< 2 mA

< 2 mA

< 2 mA

Temperature
sensor

Yes

Yes

No

AC cable

1.5 m, two-pin
earthed plug

1.5 m, two-pin
earthed plug

1.5 m, two-pin
earthed plug

DC cable

1.5 m, ring ter-
minal, M8

1.5 m, ring ter-
minal, M8

Open

International Pro-
tection (IP class)

IP67

IP67

IP67

7

LEAB Automotive GmbH

Thorshammer 6

24866 Busdorf

LEAB Automotive GmbH

4 Technical specifications

Содержание CHAMP 12 V

Страница 1: ...www leab eu USER MANUAL VERSION 5 13 07 2021 CHARGER CHAMP 12 V LEAB Automotive GmbH Thorshammer 6 24866 Busdorf ...

Страница 2: ... the 230 V mains supply 19 8 3 Connection to the 115 V mains supply 19 9 Operation 19 9 1 LED status display 19 9 2 Charging the battery 20 9 3 Charging the battery 20 9 4 Temperature sensor 20 10 Maintenance 21 11 Disposal 21 12 EU Declaration of Conformity 21 13 Appendix 22 13 1 Information on outdoor use of the PowerSystem 12 24 V 22 13 2 MagCodePowerPort installation instructions 23 13 3 MagCo...

Страница 3: ...l damage The signal word Attention indicates that there is a possibility of material damage To avoid material damage follow the instruction CAUTION Danger that can lead to minor injuries Safety instructions with the signal word CAUTION indicate a hazard which if not avoided can result in minor or moderate injury Read the safety instructions carefully and follow them to avoid the hazard WARNING Haz...

Страница 4: ...e and battery charger for permanent installation in vehicles This charger can be used to charge all types ofLead acid batteries wet gel AGM Any modifications to the device or its components are prohibited and do not conform to its intended use Keep this manual is a place where it can be ac cessed quickly 2 1 Intended Use The charger is designed for permanent installation in vehicles with 12 or 24 ...

Страница 5: ...es can cause injuries 1 Before using the battery make sure that the battery is un damaged and the electrolyte is not frozen WARNING Burns from escaping acid Acid can leak out when handling batteries 1 Wear acid proof clothing when handling batteries Notice Device defects from incorrect installation Incorrect installation can result in device defects 1 Install the device in a dry and cool location ...

Страница 6: ...eads of the charger to avoid damage In the event of damage unplug the charger immediately and contact your dealer or LEAB 3 About this product The Champ charger is a trickle and battery charger designed for permanent in stallation in vehicles With its pre programmed and fixed charging character istic all types of Lead acid batteries wet gel AGM can be charged with this charger 1 2 3 4 Fig 1 Champ ...

Страница 7: ... 1 V 14 4 V Trickle charging 13 8 V 13 5 V 13 8 V Input voltage 230 V 230 V 230 V Input values 190 V 270 V 190 V 270 V 190 V 270 V Input frequency 40 Hz 60 Hz 40 Hz 60 Hz 40 Hz 60 Hz Switching fre quency 100 kHz 100 kHz 100 kHz Degree of effi ciency max 88 88 88 Quiescent current from the battery 2 mA 2 mA 2 mA Temperature sensor Yes Yes No AC cable 1 5 m two pin earthed plug 1 5 m two pin earthed...

Страница 8: ...rging charac teristics IU1U2 pre pro grammed cannot be changed IU1U2 pre pro grammed cannot be changed IU1U2 pre pro grammed cannot be changed Charging current 17 A 17 A 17 A Ripple 3 3 3 Main charging 14 4 V 14 1 V 14 1 V Trickle charging 13 8 V 13 5 V 13 5 V Input voltage 230 V 230 V 230 V Input values 190 V 270 V 190 V 270 V 190 V 270 V Input frequency 40 Hz 60 Hz 40 Hz 60 Hz 40 Hz 60 Hz Switch...

Страница 9: ... Modell Champ 1217 Champ 1217 Champ 1217 Battery type Lead gel AGM Lead wet Lead gel AGM Battery capacity 55 Ah 170 Ah 55 Ah 170 Ah 55 Ah 170 Ah Charging charac teristics IU1U2 pre pro grammed cannot be changed IU1U2 pre pro grammed cannot be changed IU1U2 pre pro grammed cannot be changed Charging current 17 A 17 A 17 A Ripple 3 3 3 Main charging 14 4 V 14 1 V 14 4 V Trickle charging 13 8 V 13 5 ...

Страница 10: ... I Dimensions L x W x H 98 mm x 192 mm x 47 mm 98 mm x 192 mm x 47 mm 98 mm x 192 mm x 47 mm Weight 1 4 kg 1 4 kg 1 4 kg Part no 0101033829 Part no 0101033830 Part no 0101933825 Modell Champ 1217 Champ 1217 Champ 1217 Battery type Lead gel AGM Lead gel AGM Lead gel AGM Battery capacity 55 Ah 170 Ah 55 Ah 170 Ah 55 Ah 170 Ah Charging charac teristics IU1U2 pre pro grammed cannot be changed IU1U2 pr...

Страница 11: ...ug DC cable 2 5 m round cable 2x 2 5 sqm Lapp cable Ölflex 210 1 5 m FLKK binder coupling Open International Pro tection IP class IP67 IP67 IP67 Operating temper ature 30 C 70 C 30 C 70 C 30 C 70 C Protection class I I I Dimensions L x W x H 98 mm x 192 mm x 47 mm 98 mm x 192 mm x 47 mm 98 mm x 192 mm x 47 mm Weight 1 4 kg 1 4 kg 1 4 kg Part no 0101033315 Part no 0101033316 Part no 0101033318 Mode...

Страница 12: ...witching fre quency 100 kHz 100 kHz 100 kHz Degree of effi ciency max 88 88 88 Quiescent current from the battery 2 mA 2 mA 2 mA Temperature sensor Yes Yes Yes AC cable 0 2 m DEFA 0 2 m DEFA 0 2 m two pin earthed plug DC cable 1 5 m ring ter minal M8 1 5 m ring ter minal M8 1 5 m MagCode Pro International Pro tection IP class IP67 IP67 IP67 Operating temper ature 30 C 85 C 30 C 85 C 30 C 85 C Prot...

Страница 13: ...nput voltage 230 V 230 V 230 V Input values 190 V 270 V 190 V 270 V 190 V 270 V Input frequency 50 Hz 50 Hz 50 Hz Switching fre quency 100 kHz 100 kHz 100 kHz Degree of effi ciency max 88 88 88 Quiescent current from the battery 2 mA 2 mA 2 mA Temperature sensor Yes Yes Yes AC cable 2 2 m two pin earthed plug 2 2 m two pin earthed plug 2 2 m two pin earthed plug DC cable 1 5 m ring ter minal M8 1 ...

Страница 14: ...pro grammed cannot be changed Charging current 7 A 7 A 7 A Ripple 3 3 3 Main charging 14 1 V 14 1 V 14 4 V Trickle charging 13 5 V 13 5 V 13 8 V Input voltage 230 V 230 V 230 V Input values 190 V 270 V 190 V 270 V 190 V 270 V Input frequency 50 Hz 50 Hz 50 Hz Switching fre quency 100 kHz 100 kHz 100 kHz Degree of effi ciency max 88 88 88 Quiescent current from the battery 2 mA 2 mA 2 mA Temperatur...

Страница 15: ...attery capa city 55 Ah 170 Ah 55 Ah 170 Ah 55 Ah 170 Ah 55 Ah 170 Ah Charging char acteristics IU1U2 pre pro grammed can not be changed IU1U2 pre pro grammed can not be changed IU1U2 pre pro grammed can not be changed IU1U2 pre pro grammed can not be changed Charging cur rent 7 A 7 A 7 A 7 A Ripple 3 3 3 3 Main charging 14 4 V 14 4 V 14 1 V 14 1 V Trickle char ging 13 8 V 13 8 V 13 5 V 13 5 V Inpu...

Страница 16: ...IP67 Operating tem perature 30 C 85 C 30 C 85 C 30 C 85 C 30 C 85 C Protection class I I I I Dimensions L x W x H 80 mm x 155 mm x 43 mm 80 mm x 155 mm x 43 mm 80 mm x 155 mm x 43 mm 80 mm x 155 mm x 43 mm Weight 0 8 kg 0 8 kg 0 8 kg 0 8 kg 5 Package contents Name No Battery charger 1x User manual 1x 6 Charging characteristic Battery charging is fully automatic and micro processor controlled with ...

Страница 17: ...kept at a constant value As the bat tery increasingly charges the current decreases continuously and approaches a lower limit Battery Type Main charge voltage Gel battery 12 V 14 4 V Wet cell battery 12 V 14 1 V AGM battery 12 V 14 4 V U2 phase Charging with constant current In this phase the charging voltage is reduced in order to maintain the battery charge for an unlimited period and counteract...

Страница 18: ... Battery connection Notice Device defect from shortening the negative lead Do not shorten the negative lead under any circumstances as it contains a temperature sensor To install the device in the vehicle proceed as follows 1 Disconnect the battery from the vehicle power circuit WARNING Disconnect the negative lead first 2 Secure the positive lead of the device as close as possible to the vehicle ...

Страница 19: ...ains proceed as follows NOTE The charger is only suitable for connection to fused earthed 115 V mains supplies 1 Connect the mains plug to a 115 V mains supply ð The charger is connected to the 115 V mains supply 9 Operation 9 1 LED status display LED display Item Meaning Yellow LED lights up The charging process is in the I phase with maximum current The voltage drops as soon as the bat tery is c...

Страница 20: ...is installed ü The battery is connected 1 Connect the mains plug to a 115 V mains supply ð Charging starts automatically the yellow LED of the charge status indic ator lights up ð If the charging current is 15 below the maximum value the yellow and green LEDs of the charging status indicator light up ð When the battery is fully charged the green LED on the charging status indicator lights up and i...

Страница 21: ...o the battery manufacturer s instructions 11 Disposal Dispose of the device in accordance with the Waste Elec trical and Electronic Equipment Regulations WEEE The system must not be disposed of with household waste Take it to a recycling point or return it to your point of sale 12 EU Declaration of Conformity The Champ charger complies with the requirements of the following directives 2014 30 EU E...

Страница 22: ...eep the clip protected from water Clip to port connection This connection is also not waterproof At best it is protected against dripping water IP42 To prolong the life of the product the following measures should also be taken After outdoor use clean the port briefly with a cloth Remove possible deposits of metal chips on the contact side of the port and clip with an adhesive strip from time to t...

Страница 23: ...s prepared 4 Slide the MagCodePowerPort with or without spacer ring into the installation opening 5 Screw the MagCodePowerPort on the back with a nut M28 6 Connect the cables with each other by soldering crimping or with connection terminals 7 Put the fuse back in place ð The MagCodePowerPort is installed 13 3 MagCodePowerClip assembly instructions To install the device proceed as follows 1 Cut of...

Страница 24: ...w the cables into the terminals NOTE Note the polarity of the wires 6 Screw the housing together ð The device is assembled 24 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf 13 Appendix LEAB Automotive GmbH ...

Страница 25: ...25 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 13 Appendix ...

Страница 26: ...26 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf 13 Appendix LEAB Automotive GmbH ...

Страница 27: ...27 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 13 Appendix ...

Страница 28: ...usdorf Tel 49 0 4621 9 78 60 0 Fax 49 0 4621 9 78 60 260 info leab eu We make energy mobile It is prohibited to copy duplicate translate or otherwise pass on the content of this guide to third parties without the express written permission of LEAB ...

Отзывы: