LEAB Automotive -CPC
LEAB Automotive GmbH
Page - 9 -
Battery voltage 24 V (two batteries in series)
After a few seconds the CPC starts in the selected program and automatically charges the connected
battery until it is fully charged. If the orange setting LED and the red Error LED are flashing alternately
despite correctly set voltage, please check the voltage of the batteries. If the voltage is less than 20 V
the CPC will not start charging for safety reasons, in order to avoid potential hazards caused by
exhaustively discharged batteries*. Please pre-charge the batteries separately. As soon as the battery is
fully charged, the LED display changes from orange to green and the charging voltage is reduced to
maintenance charging. The battery can now be disconnected or remain connected to the battery
charger until it is used. The CPC ensures that the battery remains fully charged in the meantime.
* Only with charging program with start voltage > 0 V.
Choose the correct battery type Standard (for wet cell batteries) or Gel/AGM (for
sealed lead batteries using gel or AGM technology). Your battery will only be charged
correctly in this case.
Depending on the state of charge and size of the battery to be charged, it can take up
to 18 hours for the batteries to be fully charged again.
Batteries which are connected up to 24 V and have been exhaustively discharged to
under 20 V must always be charged individually to avoid any further damage; use a
12 V battery charger for this.
If sealed lead batteries (gel or AGM) are charged for longer periods with excessively
high voltage they can gas and dry out, thus destroying the battery.
Open wet cell batteries consume water during charging. Water must thus be refilled
regularly.
If you are not sure how to charge your batteries, please contact your specialist
dealer.
Discharged batteries must be recharged without delay, otherwise they can be
destroyed.
All manuals and user guides at all-guides.com