![LEAB 0101036081 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/leab/0101036081/0101036081_user-manual_1864559019.webp)
Switching Function of the Changeover Contact
Fig. 5: Switching
Function of the
Changeover Contact
– When the charger is switched off, pin 9 and pin 26 are
connected.
– When the charger is switched on, pin 26 and pin 18 are
connected.
Technical Data (insulation) Capacity (max. values)
Output to hous-
ing:
500 V
Max. 60 V (DC):
0.25 A
Output to ground 120 V
To install the CBL control relay, proceed as follows:
1. Solder the end of the cable to the D-sub connector.
2. Connect the wire ends to pin 26, pin 9 and pin 18.
3. Plug the D-sub connector into the connector for the
CBL control relay on the device.
ð
The CBL control relay is installed.
11 Operation
11.1 Switching On
To switch on the device, proceed as follows:
1. Connect the mains plug to a 230 V mains supply.
ð
The device is switched on.
NOTE!
After connection to the mains, the LED flashes red for 2 seconds
(device test).
NOTE!
When the battery is charging, the 'Charging' LED is lit orange.
NOTE!
When the battery is fully charged, the 'Charging complete' LED is lit
green.
19
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
LEAB Automotive GmbH
11 Operation
Содержание 0101036081
Страница 29: ...29 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...
Страница 30: ...30 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf 15 Appendix LEAB Automotive GmbH...
Страница 31: ...31 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...