![LEAB 0101036081 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/leab/0101036081/0101036081_user-manual_1864559017.webp)
Connection to the 230 V Mains
To install the device to the 230 V mains, proceed as follows:
NOTE!
The charger is only suitable for connection to fused, earthed 230 V
mains supplies.
1. Connect the mains plug to a 230 V mains supply.
ð
The charger is connected to the 230 V mains supply.
Connecting the Sensor Cable
The sensor cable measures the battery temperature (sensor cable TS) or the
battery temperature and voltage (sensor cable CTS) in order to charge the bat-
tery optimally.
To connect the sensor cable, proceed as follows:
NOTE!
When connecting, pay attention to the instructions and notes in the
sensor cable installation instructions.
1. Connect the sensor cable to the charger.
ð
The sensor cable is connected.
Connecting the D-Sub Connector
The integrated D-Sub connector allows you to control various signals.
Pin
Description
1
CAN Bus high*
2
Voltage sensor (+)
3
Temperature sensor (+)
4
LED green (+)
5
LEB yellow (+)
7
Insulated ground*
8
Pilot Brix
9
CBL relay contact, normally closed
10
CAN bus low*
11
Remote input (-)*
12
Temperature sensor (-)
17
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf
LEAB Automotive GmbH
10 Installation
Содержание 0101036081
Страница 29: ...29 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...
Страница 30: ...30 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf 15 Appendix LEAB Automotive GmbH...
Страница 31: ...31 LEAB Automotive GmbH Thorshammer 6 24866 Busdorf LEAB Automotive GmbH 15 Appendix...