Fault and Handling

Fault Phenomenon

Possible reason

Solution

LCD no display after connected with

battery

Battery Low

Battery Reverse Connection

The connection cut off

Please confirm the voltage of battery reconnect

the controller with battery firmly and correctly.

Full of sunshine vertical on solar panel,

no solar symbol and no charging symbol

on LCD.

The solar panel connection open

circuit, short circuit, or reverse

connected

Please check the cable of solar panels if they are

correct connection and firmly.

The controller displaying LVD

The battery is over discharging

Please check the system design is reasonable or

not. Please full charge the battery

The controller displaying Over Voltage

Protection of battery

The voltage of battery is too high

Please first cut off the solar panel and see if the

voltage get down normal level. If the fault do

not finish, please cut off the battery with

controller and reconnect again

Technical Data

Mode

TD4515TU

TD4615TU

System Voltage

12V/24V/48V Auto

PV Max input voltage

At minimum ambient temperature 150V(+25℃ ambient temperature
138V)

PV Max input power

12V 660W;24V 1320W;48V 2640W

12V 800W;24V 1600W;48V 3200W

MPPT Voltage range

(VBAT+2V)---120V

MPPT tracking accuracy

≥99.5%

Controller conversion efficiency

Max 98%

MPPT limited Power Output

Yes

Self-consumption

≤2W

Max Charging current

50A

60A

LVD

11.0V ADJ 9V….12V;×2/24V;×4/48V

LVR

12.6V ADJ 11V….13.5V;×2/24V;×4/48V

Float voltage

13.8V ADJ 13V….15V;×2/24V;;×4/48V

Boost voltage

14.4V ; ×2/24;×4/48V Battery Voltage less than 12.6V Start Boost2hours(Li-battery no)

Battery Over Voltage Protection 16.5V ;×2/24V;×4/48V
Reverse Connection Protection

YES

Controller Over Temperature
Protection

Yes,75℃ Start decrease charging current,85℃stop charging,65℃return to work

Charging Type

MPPT (It can support solar panel end start-up system)

Charge Control mode

3 stage:Bulk(MPPT),Boost,Float

Optional battery types

Lead Acid, Flood, Gel, Lithium iron phosphate, Ternary lithium battery

Temperature Compensation

-24 mV /℃ for 12V ;×2/24V;×2/24V;×4/48V(Li-battery no compensation)

Cooling mode

Natural heat dissipation of radiator

Working Temperature

-20℃---+50℃

Terminals scale

25mm

2

25mm

2

Waterproof grade

IP32

Size

277mm×243.8 mm×110.9mm

277mm×243.8 mm×110.9mm

Net weight

4.2KG

4.5KG

*If the controller operates in high temperature environment, please reduce the rating

Version No.:V202001

Содержание TD150V

Страница 1: ...eam series User s manual of MPPT solar charge controller MAX PV Input voltage 150V 12V 24V 48V 50A 60A Dear Users Thank you for selecting our product Please read this manual carefully before you use this product ...

Страница 2: ...l time and improve the energy utilization of solar energy system It can be used in communication base station household system street light system and monitoring system and so on Perfect electronic protection function and patent terminal structure can avoid the damage of components and due to system fault and installation error Advanced MPPT technology fast and stable track the Maximum Power Point...

Страница 3: ...e connection Overcharging Over discharging Over voltage Overload Short circuit Overtemperature 25mm2 connectors red and black connector distinguish plus and minus Using standard Modbus communication protocol based on RS 485 communication bus maximize satisfaction different occasions communication need Optional Blue tooth or WiFi communication module through the mobile phone APP can view and set th...

Страница 4: ... temperature compensation 2 USB to RS485 Communication line Optional Special cable for connecting controller communication interface RJ45 interface and USB interface of PC the standard line length is 1 5 meters it can also be customized according to the user s needs The controller can be real time monitored and parameters set by the special upper computer software 3 Bluetooth module Optional The c...

Страница 5: ... battery will be destroyed This product have limited solar panel input power function in theory no matter how much power of solar panel input the controller will limited the input power under rated power but must pay attention to the following two points 1 The short circuit of solar panel less than rated current of controller 2 The Open Circuit Voltage of solar panel increased with decreasing temp...

Страница 6: ... installation this is better for air flow cooling effect 5 Controller Connection Before connecting make sure that the system voltage matches with the selected products and whether the open circuit voltage and maximum power of the PV array are within the reasonable range of the controller The following order of connection please do not free change The controller has the function of automatic identi...

Страница 7: ...oller monitoring software operation manual 6 Start Controller Note the controller supports starting the controller from the photovoltaic array end When the automatic battery identification function is selected starting the photovoltaic array terminal first may make the controller identify the system voltage error Before connecting the power supply please confirm whether the wiring of battery termi...

Страница 8: ...MPPT mode and gradually reduce the charging current the boost charging continued 2H then go to float charging mode Due to the load capacity and generated changing the controller can t keep constant voltage charging the constant voltage charging time will be accumulated accumulate 2hours cancel boost charging mode Float Charging After entering the floating charging mode the controller will reduce t...

Страница 9: ...show battery voltage PV array voltage charging current battery type temperature of environment each parameter keep 3s Long press or button could speed loop display At the main interface short press OK button could on or off the Dry contact At the main interface long press MENU and 5S could show work log short press or could see times of LVD working days times of over current protection time of HVD...

Страница 10: ...hen the Load Working Time set to 24hours the load will keep working 24hours in no fault status When the load working time set to 23H it means the load start timer or sensor function If the battery capacity is enough the load will be started at sunset The load will work under timer setting hours or stop working till sunrise 8 Temperature Detection inside controller When the inside temperature of co...

Страница 11: ...e since the controller can be started from the photovoltaic array end the controller will be damaged when the photovoltaic array is connected right and the battery end is reversed Battery Over Voltage Protection When the battery voltage reaches the over voltage cut off point the controller will automatically stop charging and discharging the battery to prevent the battery and load from being damag...

Страница 12: ...rature 138V PV Max input power 12V 660W 24V 1320W 48V 2640W 12V 800W 24V 1600W 48V 3200W MPPT Voltage range VBAT 2V 120V MPPT tracking accuracy 99 5 Controller conversion efficiency Max 98 MPPT limited Power Output Yes Self consumption 2W Max Charging current 50A 60A LVD 11 0V ADJ 9V 12V 2 24V 4 48V LVR 12 6V ADJ 11V 13 5V 2 24V 4 48V Float voltage 13 8V ADJ 13V 15V 2 24V 4 48V Boost voltage 14 4V...

Страница 13: ...Appendix一 Mechanical dimension drawing Uunit mm ...

Отзывы: