Battery
Data about battery
Battery Type
Dry
Contact
Dry contact ON
Dry contact OFF
Dry contact Sensor and Timer mode output
Dry contact Sensor mode output
LOAD
Data about Dry contact
Dry contact working mode
Operation and Indication of controller
Main Interface
If no operation at main interface inner 10s, the main interface will cycle show battery voltage, PV array
voltage, charging current, battery type, temperature of environment, each parameter keep 3s.Long press “▲”
or “▼”button could speed loop display.
At the main interface short press “OK” button could on or off the Dry contact.
At the main interface long press
“MENU”
and “▲”5S could show work log, short press “▲”or“▼”
could see times of LVD, working days, times of over current protection, time of HVD. Press ”
↺
” could
return to main interface.
At main interface press “
MENU
” button could enter into menu interface. Press”
↺
” to exit from
any interface