Wyvern
®
2000N Banknote Timer Handbook 7
Minimum Start Credit (MSC)
Program code 5 sets the MSC so that sufficient notes must be inserted to meet a
specified price before the timer turns ON. For example if the Wyvern
®
2000N
were programmed with an MSC of $3, the timer would only start when notes to
the value of $3 are inserted.
Access the options menu as described earlier and using the UP and DOWN buttons
move to option 5. Hold the UP button until the first digit flashes and the display
shows 5-:xx where xx is the MSC. Hold the UP button down until the first two
digits flash. Use the UP and DOWN buttons to select the MSC value required.
After approximately 10 second this value is stored.
Start Delay time or Pre-Time
This is the time between inserting notes into the timer and the timer turning ON.
As soon as notes are inserted the display shows the time purchased but the load is
not switched on for a time period determined by option 6. Once option 6 times-
out the load is switched on. Setting option 6 to zero disables pre-time.
Program
Code
Description
Maximum
Value
Value Used
5
Minimum start credit
99
Program
Code
Description
Maximum
Value
Value Used
6
Start Delay Time or Pre-time
10 mins
Program
Code
Description
Maximum
Value
Channel
b1
Note 1 value
99
b2
Note 2 value
99
b3
Note 3 value
99
b4
Note 4 value
99
b5
Note 5 value
99
b6
Note 6 value
99
b7
Note 7 value
99
b8
Note 8 value
99
b9
Note 9 value
99