background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR YOUR OWN SAFETY, PLEASE READ THIS USER 
MANUAL CAREFULLY BEFORE POWERING OR 
INSTALLING YOUR LED WASH, Save it for future 
reference.  

Содержание Thunder 400

Страница 1: ...FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR LED WASH Save it for future reference ...

Страница 2: ... Cable Connectors 8 Take It To The Next Level Setting Up DMX Control 9 Fixture Linking Master Slave Mode 9 Mounting Rigging 10 4 OPERATING ADJUSTMENTS 11 The Control Panel 11 Control Panel Menu Structure 12 DMX Mode 13 Set the Starting DMX Address 13 Select the DMX Channel Mode 13 Master Slave Mode 13 Auto Standalone Modes 13 Auto Mode 13 Auto Program Speed 13 Temperature 14 Signal Loss Settings 1...

Страница 3: ... the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal condition...

Страница 4: ...nect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operate at ambient temperatures higher than 104 F 40 C In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Rep...

Страница 5: ...7 16 1 1 1 1 1 Master Dimmer 0 100 2 2 2 Segment 1 3 Intensity 0 100 3 3 3 Segment 4 6 Intensity 0 100 4 4 4 Segment 7 9 Intensity 0 100 2 2 5 5 5 Flash duration 0 full on 1 3 3 6 6 6 Strobe rate 0 30Hz 4 7 7 Built In Effects 8 Segment 1 Intensity 0 100 9 Segment 2 Intensity 0 100 10 Segment 3 Intensity 0 100 11 Segment 4 Intensity 0 100 12 Segment 5 Intensity 0 100 13 Segment 6 Intensity 0 100 14...

Страница 6: ...p Picture Figure 2 The Rear Connections 1452pcs Bright LEDs Locking Knobs Mounting Bracket Durable Cast Aluminum Housing Natural Convection Heat Sink Cooling Easy To Use4 Button LCD Control Panel AC Power Out 3 pin XLR AC Power in ...

Страница 7: ...6 Figure 3 Setting on the floor ...

Страница 8: ...f Fixtures Follow the guide below to properly link fixtures Power the first fixture in the chain with a standard cable provided with fixture Then jump each subsequent fixture with a properly rated jumper cable WARNING DO NOT POWER LINK MORE THAN 4 FIXTURES IN ONE SINGLE CHAIN ELECTRICALOVERLOAD MAY OCCUR Do not link more than 4 fixtures in a single chain Electrical overload may occur and damage fi...

Страница 9: ... male XLR connector on one end and a female XLR connector on the other end CAUTION Do not allow contact between the common and the fixture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other A Word on Terminati...

Страница 10: ...o the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connector to the input connector of the next fixture consisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on A quick note Often the setup for Master Slave and Standal...

Страница 11: ...not mount the fixture in the ventilation path of a nearby heating supply duct The heated airflow will cause fixture failure due to overheating SAFETY EYEBOLT CABLE Install the included eyebolt into the threaded hole on the back of the housing see images above Then install the safety cable to the eyebolt Anchor the safety cable to the truss or other secure mounting surface Overhead and wall install...

Страница 12: ...menu options in descending order Scrolls through menu options in ascending order Used to store the current menu or option within a menu The LCD control panel display shows the menu items you select from the menu map on page 12 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item press ENTER To navigate th...

Страница 13: ...l Mode Channel 1 1ch DMX mode Channel 3 1ch DMX mode Channel 4 1ch DMX mode Channel 6 1ch DMX mode Channel 7 1ch DMX mode Channel 16 1ch DMX mode Pixel 3 3ch DMX pixel control Pixel 9 9ch DMX pixel control Key Mode Key Lock Menu buttons lock after 30sec of inactivity push more than once to temporarily unlock buttons Key Unlock Menu buttons are not locked DMX Status Value Hold Holds the last DMX va...

Страница 14: ...tton until you reach the Address screen Master Slave Mode 1 Disconnect fixture s from any DMX signal source 2 Set each fixture to matching DMX modes 3 Connect all fixtures together via DMX The first fixture in the DMX chain will be the master followed by the slave fixtures 4 Connect DMX controller to the master unit for DMX control Load Default Settings 1 Press the UP DOWN buttons until you reach ...

Страница 15: ...ress the ENTER button to confirm LCD Display On Auto Off Display mode On will keep the LCD illuminated continually Auto will shut the display off after 30 seconds of inactivity 1 Press the UP DOWN buttons until you reach Config 2 Push the ENTER button and navigate to Display Mode 3 Push the ENTER button then select either On or Auto and press the ENTER button Key Button Protection Mode With Key Lo...

Страница 16: ...ty 0 100 10 000 255 Segment 3 Intensity 0 100 11 000 255 Segment 4 Intensity 0 100 12 000 255 Segment 5 Intensity 0 100 13 000 255 Segment 6 Intensity 0 100 14 000 255 Segment 7 Intensity 0 100 15 000 255 Segment 8 Intensity 0 100 16 000 255 Segment 9 Intensity 0 100 DMX Values In Depth 7 Channel Mode Ch Value Function 1 000 255 Dimmer 0 100 2 000 255 Segment 1 3 Intensity 0 100 3 000 255 Segment ...

Страница 17: ...2 214 215 255 Built In Programs No function Ramp up effect slow fast Ramp down effect slow fast Ramp up down effect slow fast Random effect slow fast Lightning effect slow fast Spike effect DMX Values In Depth 3 Channel Mode Ch Value Function 1 000 255 Dimmer 0 100 2 000 255 Flash Duration 0 100 3 000 255 Strobe Rate 0 30Hz DMX Values In Depth 1 Channel Mode Ch Value Function 1 000 255 Dimmer 0 10...

Страница 18: ...ay have shut itself off due to high heat This is to protect the fixture from overheating No Light Output Check to ensure fixture is operating under No Light Output Check to ensure fixture is operating under correct mode IE sound active auto DMX Etc if applicable Chase Speed Too Fast Slow Check to ensure proper setup of speed adjustment No Power Check fuse AC cord and circuit for malfunction Blown ...

Страница 19: ... as a safety cable rated for your fixture type and size Check the power cord as well make sure there is no damage that could cause electrical shock never remove the ground prong There are no user servicable parts in this fixture Do not attempt to open and repair this fixture Return to the factory for repair Tech Specs Weight Dimensions Width 17 8 in 45 cm Base 15 7 in 39 8 cm Depth 3 in 7 4 cm Bas...