Parts with extra low voltage (not exceeding 12V) must be inaccessible to a person in
the spa / hot tub. Earthed appliances must be permanently connected to fixed wiring.
Parts incorporating electrical components must be located or fixed so that they
cannot fall into the spa / hot tub.
Means for disconnection must be used with fixed wiring configurations in accordance
with local wiring rules
.
IMPORTANT:
To allow the GFCI to function properly, connect the white Neutral
wire from the
spa
/ hot tub to the Neutral terminal on the GFCI breaker, not the Neu-
tral bus bar in the GFCI breaker box. An improperly connected Neutral causes the
GFCI breaker to trip.
Figure 3 - GFCI Wiring
Disconnect the electrical power before servicing. Before obtaining
access to terminals, all supply circuits must be disconnected.