background image

 

 

 

    

G. Balanced/Unbalanced Switch 

The XLR outputs of the MP10 are electronically balanced and should not be connected to 
an unbalanced input without first setting the rear panel switch to “unbal.” Doing so will not 
cause damage to the amplifiers, but will raise the distortion level of the outputs 
significantly. The switch is located between the two sets of XLR connectors and is 
labeled “bal” and “unbal.” The peak output level is reduced from +24 dBu to +18dBu 
when the switch is set to “unbal.” After AC power is applied, the setting of this switch is 
displayed in the left GAIN display during initialization as “ba” for balanced and “Ub” for 
unbalanced. 
 

SPECIFICATIONS: 

 
Distortion

Measured at -3dBFS (21dBu) at 1kHz, 10kHz, &20kHz: 

 
 

 

Gain Setting  20  

Less than 0.00070%dBFS  

 

 

Gain Setting  40  

Less than 0.00090%dBFS  

 

 

Gain Setting  60  

Less than 0.00800%dBFS  

 
Noise

Input referenced noise at Gain Setting 40 with -999dBr input 

 

 

 

 

 

150 Ohm source 

Less than -124dBu (Unweighted) 

 

 

 

 

 

Less than -127dBu (A-Weighted) 

 

 

 

 

 

 

 

Inputs- Transformer-free electronically balanced Pin 2 “+” XLR inputs with common hi/lo 
impedance switch. 
 
Phantom Power- +48 volts Phantom power for condenser microphones, can be enabled or 
disabled for each input channel individually using front panel switch. 
 
Outputs- Transformer-free electronically balanced outputs. Rear panel switch for balanced Pin 2 
“+” or unbalanced Pin 2 “Hot” operation.  
 
Meter- 14 segment LED meter per channel, displays output signals ranging from -42 to 0dB 
below peak output level. Maximum balanced peak output 24dBu, maximum unbalanced peak 
output is 18dBu. 
 
Dimensions and Weight- 8”wide x 10.75” deep* x 1.75” high, 4.5 lbs 
*depth includes clearance for front and rear panel switches and connectors 
 
AC Power: 
Voltage 90-264 VAC, Frequency 47-63Hz, Current 0.1A 
Fuse Rating 4A “Fast Blow” * 
*Subject to change! Please always check the rating on the fuse and the one printed next to the 
fuse holder on the power supply PC board before replacement. Replace the fuse ONLY with a 
fuse of the same rating. If you have any questions, contact: 

[email protected]

 

 
 

ACCESSORIES 

 
Included in box: U.S.A. Power Cord, Warranty Card, This User’s Manual 
Optional: LavryBlack Series 19 inch rack-mount kit. This kit is designed to mount two LavryBlack 
units side-by-side in a 1U rack space. 
 

Содержание MP10

Страница 1: ...yBlack Series Model MP10 Stereo Microphone Preamplifier Lavry Engineering Inc P O Box 4602 Rolling Bay WA 98061 http lavryengineering com email techsupport lavryengineering com Version 1 0 September 5 2008 ...

Страница 2: ......

Страница 3: ...the input impedance of both channels to be matched to the type of microphones being used For example lo z would be used for Dynamic and Condenser microphones and hi z would be used for Ribbon Mic s The inputs are a transformer free electronically balanced design for accurate and extended bass response with excellent rejection of unwanted hum and noise ANALOG OUTPUTS The transformer free electronic...

Страница 4: ...able and output levels suitable for both unbalanced 10 and balanced 4 level inputs When the output switch is set to unbal the maximum output level is reduced by 6 dB from the maximum level for balanced operation of 24 dBu Even so when feeding the output of the MP10 to an unbalanced 10 level input care should be taken to set the gain so that the peak signal level displayed on the MP10 s meter does ...

Страница 5: ... XLR inputs with common hi lo impedance switch Phantom Power 48 volts Phantom power for condenser microphones can be enabled or disabled for each input channel individually using front panel switch Outputs Transformer free electronically balanced outputs Rear panel switch for balanced Pin 2 or unbalanced Pin 2 Hot operation Meter 14 segment LED meter per channel displays output signals ranging fro...

Страница 6: ...r similar businesses This limited warranty gives you specific legal rights You may have others which vary from state jurisdiction to state jurisdiction LIMITS AND EXCLUSIONS LAVRY ENGINEERING DOES NOT BY VIRTUE OF THIS AGREEMENT OR BY ANY COURSE OF PERFORMANCE COURSE OF DEALING OR USAGE OF TRADE MAKE ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILI...

Отзывы: