operation
FUELING THE HEATER
Temperature Limit Control:
This heater is equipped with a Temperature
Limit Control designed to turn the heater off should the internal
temperature rise to an unsafe level. If this device activates and turns your
heater off, it may require service. Once the temperature falls below the
reset temperature, you will be able to start your heater.
Electrical System Protection:
The heaters’ electrical system is protected
by a circuit breaker that protects the system components from damage. If
the heater fails, check the fuse first, and replace if necessary.
Flame Sensor:
The heater uses a photocell to “see” the flame in the
combustion chamber. Should the flame extinguish, the sensor will stop
electrical current and the heater will shut off.
CAUTION
• Never fill the fuel tank indoors. Always fill the tank outdoors. be sure
that the heater is on level ground when fueling, and never overfill the
fuel tank.
WARNING
• Never refuel this heater while it is hot or operating. fire or explosion
could result.
It is always a good idea to fire the heater outdoors for the fist time. This
will allow any oils used in the manufacturing process to be burned off in a
safe environment. This initial burn should last at least 10 minutes.
HK175FH_LavorPro Heater_Manual_2016.indd 15
2016-04-01 11:39 AM
Содержание HK175FH
Страница 2: ...2 HK175FH_LavorPro Heater_Manual_2016 indd 2 2016 04 01 11 39 AM...
Страница 12: ...12 FEATURES DIMENSIONS specifications HK175FH_LavorPro Heater_Manual_2016 indd 12 2016 04 01 11 39 AM...
Страница 22: ...22 Diagrams WIRING DIAGRAM diagrams HK175FH_LavorPro Heater_Manual_2016 indd 22 2016 04 01 11 39 AM...
Страница 23: ...23 PARTS BREAKDOWN diagrams HK175FH_LavorPro Heater_Manual_2016 indd 23 2016 04 01 11 39 AM...
Страница 27: ...27 HK175FH_LavorPro Heater_Manual_2016 indd 27 2016 04 01 11 39 AM...
Страница 28: ...28 HK175FH_LavorPro Heater_Manual_2016 indd 28 2016 04 01 11 39 AM...