manualshive.com logo in svg
background image

GB

8

    Maintenance     Cleaning     Disposal     Troubleshooting

       from the gun.

2)Clean the nozzle orifice with the nozzle

cleaning pin       provided.

3)Rinse the nozzle         under running water.

Disposal

• Disposal must be carried out in accordance

with applicable environmental legislation.

• The appliance and its accessories must

be disposed of in accordance with the
materials used in their construction.

• Disposal must be carried out in accordance

with applicable local legislation. Contact
your municipality for the nearest refuse
dumping site.

• As owner of an electrical or electronic

product, you are not allowed by law
(according to EU-Directive 2002/96/EC of
27 January 2003 on waste electrical and
electronic equipment and the particular
national laws of the EU-Member States
transforming this Directive) to dispose of
this product or its electrical/electronic
accessories as unsorted domestic waste.
You shall use the designated gratis
possibilities for return instead

Troubleshooting

Fault

Cause

Repair

The pump does not
start when the switch
is pressed.

• The plug is not properly

connected to the
socket.

• Faulty electric plug.
• The mains voltage is

insufficient.

• The gauge of the

electrical power lead is
too small.

• The pump has cut out.

• Connect the plug to the

power socket correctly.

• Have the electrical

socket checked.

• Check that the system

is suitable.

• See paragraph “Safety

notes / electrical
connection”.

• Turn the switch to ON

while keeping the gun
lever pressed; if the
problem persists
contact an authorised
service centre.

Fault

Cause

Repair

The machine starts, but
no water comes out.

• Pump, hoses or

accessories frozen.

• No water supply.
• Unit water filter clogged.
• Nozzle or spray gun

orifice clogged.

• Allow the pump and

hoses to thaw.

• Connect the machine to

the water supply system
and turn on the tap.

3

13

3

Содержание SUPERWASH 160

Страница 1: ...or the first time Assembling the appliance pag 4 Usage Connecting to the water mains page 5 Installing the gun page 6 Automatic Stop System page 6 Gun with pressure gauge page 6 Gun safety catch page...

Страница 2: ...m inappropriate use or modifications Do not direct the nozzle toward mechanical parts containing lubricant grease as the grease will dissolve and spread over the surrounding ground Vehicle tyres tyre...

Страница 3: ...liance Children are often not aware of the hazards that household appliances may present This appliance is intended for outdoor use only Never use the appliance if the power lead or any major componen...

Страница 4: ...t Avoid tangling Do not bend the hose or subject it to high stress or strain Never start the high pressure cleaner without first completely unwinding the high pressure hose Before unwinding or winding...

Страница 5: ...hose end will be attached to the gun 4 Photo sequence G Turn the drum keeping the hose connector on the left hand side Fit the previously assembled drum onto the bracket at the rear of the unit Press...

Страница 6: ...tomatically aspirates and mixes the detergent Nozzle with pressure regulator You may adjust the operating pressure by turning the knob at the end of the nozzle see also photo C To reduce operating pre...

Страница 7: ...purge the pressure and disconnect the unit from the mains electricity and water Ensure that the air intake vents are always clean so that air can circulate freely inside the unit To ensure safe opera...

Страница 8: ...ose of this product or its electrical electronic accessories as unsorted domestic waste You shall use the designated gratis possibilities for return instead Troubleshooting Fault Cause Repair The pump...

Страница 9: ...or dirty Air in intake water Suction filter fouled Suction or delivery valves fouled or worn Gaskets worn Pressure regulator valve gaskets worn Repair Remove the lance from the gun and clean the nozzl...

Страница 10: ...se and gun supplied ready connected Air in intake water Water leak from the gun Water leak from the pump Tighten the connection ahead of the quick release connector using 2 suitable spanners Connect t...