9. TROUBLESHOOTING
Index of Problems and Solutions
IMPORTANT: To check the LOGO messages press the up arrow
button to light the screen. After the corrective action, press the
STOP button to clear the LGO message.
VACUUM ISSUE OR SYMPTOM
POSSIBLE CAUSE
CORRECTIVE ACTION
MOTOR DOES NOT START
NO POWER
CONNECT THE MACHINE
SWITCH DEFECTIVE
REPLACE
MOTOR DOES NOT START AND FORCED
CLEANING BUTTON BLINKS
WRONG PHASE SEQUENCE
OPEN THE CONTROL BOX AND CHECK LOGO FOR MESSAGES .
CONNECT IN THE CORRECT SEQUENCE
EMERGENCY STOP BUTTON IS ACTIVATED
OPEN THE CONTROL BOX AND CHECK LOGO FOR MESSAGES.
RELEASE THE EMERGENCY STOP BUTTON
MOTOR STOPS IMMEDIATELY AND FORCED
CLEANING BUTTON BLINKS
MOTOR OVERLOAD
CLEAN THE FILTER (WHILE THE VACUUM IS TURNED OFF). REPLACE IF
NECESSARY.
OPEN THE CONTROL BOX AND CHECK LOGO FOR MESSAGES.
RELEASE THE MOTOR PROTECTION “QM”.
IF THE MESSAGE APPEARS AGAIN, CONTACT TO SUPERABRASIVE
TECHNICAL SUPPORT.
MOTOR OVERTEMP
OPEN THE CONTROL BOX AND CHECK LOGO FOR MESSAGES.
WAIT TO COOL. IF THE MESSAGE APPEARS AGAIN, CONTACT TO
SUPERABRASIVE TECHNICAL SUPPORT.
MOTOR BEARINGS OVERTEMP
OPEN THE CONTROL BOX AND CHECK LOGO FOR MESSAGES.
WAIT TO COOL. IF THE MESSAGE APPEARS AGAIN, CONTACT TO
SUPERABRASIVE TECHNICAL SUPPORT.
MOTOR RUNS BUT THERE IS NO SUCTION
HOSE NOT CONNECTED
CONNECT THE HOSE
THE VACUUM HOSE HAS AN OBSTRUCTION OR HOLES
PRESENT
CHECK THE HOSE FOR OBSTRUCTIONS AND CLEAR THEM AS
NECESSARY. REPLACE THE HOSE IF VISIBLE HOLES ARE PRESENT
THE VACUUM FILTER(S) HAS
EXCESSIVE BLOCKAGE
ACTIVATE THE FILTER SHAKER LEVER TO CLEAN THE FILTER (WHILE THE
VACUUM IS TURNED OFF). REPLACE IF NECESSARY
NO PLASTIC BAG
INSTALL PLASTIC BAG
MOTOR RUNS BUT SUCTION IS POOR
DAMAGE TO THE HOSE
CHANGE HOSE
BLOCKED FILTER
REMOVE THE FILTER(S) FROM THE VACUUM AND INSPECT FOR HOLES
OR TEARS. REPLACE IF NECESSARY
TOP COVER LOOSE
ADJUST
THE VACUUM DUST
CONTAINER/BAG IS FULL
FOLLOW THE PROCEDURE TO CLEAN THE MAIN FILTER, TURN OFF THE
MOTORS AND CLEAN THE DUST COLLECTOR. REPLACE THE
LONGOPAC® SECTION OF BAG FILLED WITH DUST AND DEBRIS
THE VACUUM SEALS ARE MISALIGNED OR DAMAGED
MAKE SURE ALL RUBBER SEALS ARE INSTALLED AND ALIGNED
PROPERLY. REPLACE IF ANY VISIBLE DAMAGE IS PRESENT
DUST IS LEAKING FROM THE VACUUM DURING
OPERATION
DEFECTIVE OR LOOSE FILTER
ADJUST OR CHANGE
AUTOMATIC FILTER CLEANING SYSTEM
IS NOT RUNNING
AND FORCED CLEANING BUTTON BLINKS
NO POWER SUPPLY TO THE LOGO OR THE ACTUATORS
CHECK THE CIRCUIT BREAKER “F4” IN CONTROL BOARD
ABNORMAL NOISE
ORDER SERVICE
Содержание V32E
Страница 2: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 2...
Страница 24: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 24...
Страница 25: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 25 8 1 2 V32E 230V...
Страница 26: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 26...
Страница 27: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 27 8 1 3 V32E 480V...
Страница 28: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 28...
Страница 37: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 37 10 LAVINA VACUUM ADAPTERS AND CONNECTIONS...
Страница 42: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 42 11 3 MAIN FILTER CHAMBER Figure 21 3...
Страница 48: ...Superabrasive Owner s manual original language Lavina V32E 01 2020 48 11 7 POWER UNIT Figure 11 7...