42
Row 2 middle cell shows the number of the profile. This profile has a number 3. This tells
the 6300 that this profile is to be loaded in as profile number 3. When profile 3 is executed
on the 6300, this “Sample” profile will be executed. This number can be any number
between 1 and 20. When this profile is downloaded into the 6300 it will overwrite the
previous profile that was resident in the 6300 as number 3.
Row 2 right cell shows the height correction. This should normally be zero.
Rows 3 through 14 are the points of the profile. This profile has only 12 points. For each of
these points the columns contain the following information:
Column
Information
A
Pitot units
B
Pitot mode
C
Pitot target value
D
Static units
E
Static mode
F
Static target value
G
Rate target value
In the sample profile, Row 3, which is the first point in the profile, tells the 6300 to go in
Control mode to 100 knots on the Pitot side, and in Control mode to 0 feet at 6000 feet/min
on the Static side.
Row 4 (point 2) makes the 6300 go to 200 knots and 0 feet at 6000 ft/min.
Row 5 (point 3) puts the Pitot side into Leak mode while still keeping Static in Control at 0
feet.
Row 6 (point 4) puts the Pitot side back into Control and takes it down to 100 knots. The
Static side is simultaneously moved up to 1000 feet at 6000 ft/min.
Row 7 (point 5) takes Pitot up to 200 knots and Static up to 5000 feet at 6000 ft/min.
Row 8 (point 6) takes Pitot up to 300 knots and Static up to 10,000 feet at 6000 ft/min.
Row 9 (point 7) takes Pitot down to 100 knots and Static up to 18,000 feet at 6000 ft/min.
Row 10 (point 8) keeps Pitot at 100 knots and puts Static into Leak mode while at 18,000
feet.
Row 11 (point 9) keeps Pitot at 100 knots and ramps Static in Control mode to 30,000 feet at
6000 ft/min.
Row 12 (point 10) keeps Pitot at 100 knots and ramps Static to 50,000 feet at 6000 ft/min.