30
To accept the setting of the 1
st
leak-timer and move the arrow to the 2
nd
leak-timer, press
ENTER. The screen will appear as below. Change the 2
nd
leak-timer value if desired, using
the Arrow keys. The leak-timer value must be changed before the elapsed time reaches 58
seconds. The 2
nd
leak-timer value can be adjusted between 2 and 19 minutes.
100.0 knots 0 ft/min. 15000 feet
1m:
2m:
3m: 0:08
To accept the setting of the 2
nd
leak-timer and move the arrow to the 3
rd
leak-timer, press
ENTER. The screen will appear as below. Change the 3
rd
leak-timer value if desired, using the
Arrow keys. The leak-timer value must be changed before the elapsed time reaches 58
seconds. The 3
rd
leak-timer value can be adjusted between 3 and 20 minutes.
100.0 knots 0 ft/min. 15000 feet
1m:
2m:
3m:
0:15
To accept the setting of the 3
rd
leak-timer and complete the leak-timer settings, press ENTER.
The arrow will be cleared from the display.
It is highly recommended that the leak-timer values be checked and adjusted, if
necessary, when the unit is first turned ON, by putting both Pitot and Static outputs into
Leak mode simultaneously. This will prevent having to set them when the aircraft is
actually being leak-checked.
The leak-timer values are maintained through a power OFF cycle.
How the Timed-Leak screen is updated:
The first line of the screen, which shows the current Actual values, is updated every 0.25
seconds. The elapsed time is updated every second.
Assuming that the leak-timers are set to 1, 2 and 3 minutes, when the elapsed time reaches
1:02 (2 seconds after the elapsed time reaches the first leak-time) , the leak screen will be
Содержание 6300
Страница 10: ...3 ...
Страница 11: ...4 ...
Страница 15: ...8 ...
Страница 16: ...9 ...
Страница 71: ...64 APPENDIX C CONNECTOR PIN OUTS ...