20
The value will continue to blink until the GO key is pressed. Only after the GO key is pressed,
will the value become effective.
If you change your mind and want to abort the new value entry, press CANCEL to exit the
value entry mode. You can press CANCEL even when the value is blinking. In the above
example, if you were to press CANCEL the old Pt target value of 20.0 will remain effective.
If there is an error in the value being entered then that error will be displayed on line 4 of the
display. To clear the error, enter CANCEL or CLR. This will also erase the erroneous value
and the previous value will stay in effect. Most errors are caused because a value entered is
outside the limits.
If the new value does not blink after pressing ENTER and no error message appears, then
there is a communication problem between the Remote unit and the main unit. Please abort
and contact the factory.
If GO is pressed after ENTERing the value, the 6300-M4 will try to achieve this new target
value
ONLY
IF
the Pitot output is in the CONTROL mode. Therefore, it is desired that both
Pitot and Static values be entered so that both are blinking before the GO key is pressed.
Static target value:
For entering Ps or altitude target values, press the Ps / ALTITUDE key
and then follow the same process as described above.
Climb target value:
For entering Ps rate or CLIMB target values, press the Ps RATE / CLIMB
key and then follow the same process as described above.
Note that while entering Climb values, it is NOT necessary to include the sign of the rate of
climb. The 6300-M4 will automatically determine the direction of the rate of change. The
displayed actual value will, however, indicate with a minus sign that the rate of change is a
descent instead of a climb.
Target Value Jog
Each of the three target values can be jogged up or down in small increments by using the
arrow keys. This is done to help the operator achieve a perfect reading on the instrument in
the aircraft, by bumping the set-point in small increments.
To jog a value, select the value by pressing the appropriate target value key and then use the