43
Connecting to the water supply
Permitted water pressure
The water pressure must be at least 0.5bar (=5N/cm
2
=0.05MPa) and
may be a maximum of 10bar (=100N/cm
2
=1MPa).
–
If more than 10bar: Connect a pressure reduction valve.
–
If less than 0.5bar: Disconnect the appliance end of the inlet hose
from the solenoid inlet valve and remove the flow meter. (In addition
remove the filter using pointed pliers and take out the rubber gasket
behind it.) Re-insert the filter.
Water inlet
Attention!
•
An inlet hose is supplied and can be found inside the machine drum.
•
Do not use already employed hoses for water connection.
•
This appliance must be connected to a cold water supply.
1.
Open the porthole and extract the inlet hose.
2.
Connect the hose with the angled
connection to the machine.
Important!
Do not place the inlet hose down-
wards. Angle the hose to the left
or right depending on the position
of your water tap.
3.
Set the hose correctly by loosening
the ring nut. After positioning the
inlet hose, be sure to tighten the
ring nut again to prevent leaks.