Commands and Parameters 

 

INI Command

 

Description

 

ltm-setup-rev=x 

This keyword is set by the configuration manager to indicate the last time the file was updated. 

 

 

product-family=x 

The “product-family=2” must be set for eSynC products supporting battery modulation. 

 
The permitted range is 1 to 2. The value 1 is used for SimulCharge products (such as eSTS). 
The default is 2. 
 

btty-protection-type=x 

The “btty-protection-type” keyword selects the battery protection mechanism to be used. The options 
are 1 or 2 based on the mobile device being used. 
 
The selection used must match the mobile device capabilities. Mobile devices may only implement a 
sub-set of the USB-C PD specification, which requires LAVA test each model to verify the level of 
compatibility.  
 
eSynC Mk1 products only the “btty-protection-type=1”. 
eSynC Mk2 products support both “btty-protection-type=1” and “btty-protection-type=2”. 
 
Using “btty-protection-type=2” with an eSynC Mk1 results in the device charging to 100%. 

board-type=x

 

 

The “board-type” keyword 

is not used with eSynC

 products. 

With “product-type=1” set, the “board-type” keyword is ignored and the “btty-protection-type” 
keyword is used to define the battery protection type.  

 

 

btty-upper-threshold=x

 

 

The standard upper limit for battery charging as a percentage. 
The permitted range is 20 to 100. 
The default is 75.

 

btty-lower-threshold=x

 

 

The standard lower limit for battery charging as a percentage. 
The permitted range is 1 to 100. 
The default is 45.

 

btty-cycle-limit-on-start=x

 

 

The number of charge cycles after startup before a "full" charge cycle is forced. 
For a "full" charge cycle the btty-cycle-lower-threshold and btty-cycle-upper-threshold are used. 
The permitted range is 0 to 100. A value of 1 is treated as 2. 
The default is 2.

 

btty-cycle-limit=x

 

 

The number of charge cycles before a "full" charge cycle is used. 
For a "full" charge cycle the btty-cycle-lower-threshold and btty-cycle-upper-threshold are used. 
The permitted range is 1 to 9999. Values less than 4 are treated as 4. 
The default is 50.

 

no-btty-modulation=x

 

 

This command can be used to disable the battery modulation. The LTM application continues to run 
and provide other extended features such as network recover and screen brightness management. 
A “1” results in: no battery modulation and all battery thresholds are internally set to 100. 
A “0” permits battery modulation. 
Disabling battery modulation is not recommended. The ability is present for internal testing. 
The permitted range is 0 to 1. 
The default is 0. Sorry for the use of reverse logic.

 

 

 

permit-ethernet=x

 

This command is used to enable the Ethernet related features of LTM. 
The permitted range is 0 to 1. A 1 permits the Ethernet features. A 0 disables the Ethernet features. 
The default is 1.

 

dhcp-recovery=x

 

 

A dhcp-recovery value of 1 or 2 enables the Network/DHCP Recovery mechanism. 
When the network connection is lacking for approximately 1 minute, a network reset is attempted. 
A value of 0 disables the mechanism. 
The permitted range is 0 to 2. The default is 1. 
 
A dhcp-recovery value of 1 results in subsequent recovery attempts taking place after 2, 3, 5, and then 8 
minutes. After the first four recovery attempts, then subsequent attempts are every 8 minutes.  
 
A dhcp-recovery value of 2 results in subsequent recovery attempts taking place every 2 minutes. 

 

Содержание eSynC-E

Страница 1: ...ng 6 USB 2 0 Ports for User Accessories 7 LAVA Tablet Manager LTM Application 7 Battery Modulation 8 Wired Network Operation 10 Network Recovery Operation 11 Screen Brightness Management 12 Power Opti...

Страница 2: ...Family Reference Manual C03 2 Vulcan St Toronto ON Tel 1 416 674 5942 www lavalink com Canada M9W 1L2 Toll Free US Canada 800 241 5282 2 of 36 The LAVA Device Info Utility 33 The LTM Setup Utility 34...

Страница 3: ...e LTM application must be installed to support an eSynC product The eSynC products use features specific to a group of Samsung mobile devices eSynC Product Family Overview Product USB 2 0 Ports Type A...

Страница 4: ...d on available from many Network Switch vendors The eSynC models without PoE require a USB Power Supply with a USB C plug The Wall USB Charger provided with the tablet or mobile phone is an ideal choi...

Страница 5: ...42 www lavalink com Canada M9W 1L2 Toll Free US Canada 800 241 5282 5 of 36 Note LTM v4 and v5 are exactly the same The only difference is LTM v4 must be side loaded while v5 is available in the Googl...

Страница 6: ...eration Up to 5 USB 2 0 receptacles The eSynC extended features rely on the LAVA product working in unison with the LAVA Tablet Manager application Installation of the LTM application is mandatory bef...

Страница 7: ...be installed on the mobile device to manage each LAVA product The LTM application runs in the background on the mobile device LTM works with Android v5 1 1 and newer LTM is available through the Goog...

Страница 8: ...versions Battery Modulation The Battery Modulation feature helps reduce stress on the device s battery Battery Modulation is a feature in which the battery is charged up to an upper set point and the...

Страница 9: ...alibration of the battery level to battery voltage by the device The btty cycle limit on start 2 results in the device being allowed to charge up to 100 two cycles after the LTM application is started...

Страница 10: ...assignments or dynamic address assignments via DHCP The menu reports if the Ethernet adapter is active When using DHCP the device attempts to fetch the network addressing information from a DHCP serv...

Страница 11: ...restarted the device has lost the wired network connection The DHCP behavior is a serious issue for an enclosure based system There is no software only solution for a non rooted device The LTM applic...

Страница 12: ...of 100 yet significantly reduces heat generation During the night time window selecting a very low screen level reduces heat generation dramatically Setting a level of 15 allows the screen to be seen...

Страница 13: ...ranty The eSynC PE and eSynC P2UE support Power over Ethernet PoE and therefore can operate using power provided over the network cable Using PoE can resolve the problem of getting power to a device w...

Страница 14: ...f power for the device the eSynC and attached USB accessories The 10 4 watt limit allows the unit to be treated as a PoE Class 0 device by a PoE switch The eSynC PoE Power Supply is capable of supplyi...

Страница 15: ...ct SLD mechanisms These features add an extra level of protection for some rare conditions seen in a few device models The Low Level Detect LLD monitors the device battery level In some rare cases the...

Страница 16: ...cts referred to in this document as the eSynC Mk1 and eSynC Mk2 The eSynC Mk1 is the original series of products The second generation products are referred to as eSynC Mk2 and were introduced in earl...

Страница 17: ...on eSynC products without Power over Ethernet or a built in voltage converter This input provides power for the eSynC product the device and for attached USB accessories The eSynC product does not fu...

Страница 18: ...uct the cable quality and length must be selected to ensure that the voltage reaching each accessory is at least 4 75 volts as a general rule Many devices such as mice operate at a lower voltage than...

Страница 19: ...n the LAVA product is 80 efficient at full load therefore 12 watts into the product results in 10 watts for system use A power supply with a higher power rating than the required minimum is always per...

Страница 20: ...AVA product is waiting for a mobile device to be attached 1 second blink on both LEDs and when one LED is on the other is off The LAVA product has detected a mobile device and is waiting for LTM to co...

Страница 21: ...onnected to the device The USB Activity flashes when there is traffic between the device and an eSynC product The Link Activity is a green indicator The Link Activity is solid green when the Ethernet...

Страница 22: ...the eSynC PE and eSynC P2UE products This port is attached to a Network Switch which has been configured for PoE operation Use of a PoE Injector allows a non PoE switch to be used with the eSynC PE a...

Страница 23: ...is type of device makes this type of interface still attractive in many devices The majority of serial ports use a device referred to as a Universal Asynchronous Receiver Transmitter or UART for short...

Страница 24: ...smartphone When combined with the LTM application both products support the extended features of Battery Modulation and Screen Brightness Management The eSynC 1U OEM has an internal USB 2 0 Hub which...

Страница 25: ...least 5 volts for proper device operation Any 5 volt regulated DC power supply can be used with these boards including USB Power banks The preferred voltage at the board input is 5 1 to 5 25 volts The...

Страница 26: ...be modified using a text editor on a PC as most devices do not have a suitable editor installed Changes to the file are copied to the InternalStorage Android data com lava tabletmanager7 files folder...

Страница 27: ...45 btty cycle limit on start x The number of charge cycles after startup before a full charge cycle is forced For a full charge cycle the btty cycle lower threshold and btty cycle upper threshold are...

Страница 28: ...1 time The default is 1 which disables the brightness timers brightness level1 x Screen brightness used by brightness level1 time The permitted range is 0 to 100 The default is 15 Invalid values are r...

Страница 29: ...00 The permitted range is 0 to 100 A 0 disables logging The default is 0 user debug x This command enables a set of Toast based status messages suitable for the user The messages report the general st...

Страница 30: ...es Comments 0 No status messages 1 LTM ethernet connected Reported when the Ethernet state changes from not connected to connected 1 LTM ethernet not connected Reported when the Ethernet state changes...

Страница 31: ...ata The first line after the header contains a short title for each field which is useful for some graphing applications Diagnostic Log File Field Descriptions Field Title Description 1 ID The ID fiel...

Страница 32: ...e When product family 1 is used board type defines the protection type When product family 2 is used btty protection type defines the protection type LTM START product family 2 btty protection type 1...

Страница 33: ...C and eSTS products have an internal 2 pin jumper labeled MODE When this jumper is installed the extended features of the product are disabled and the product cannot be detected by this utility The ju...

Страница 34: ...LTM The LTM v1 v2 and v3 had no display component built in The LTM v4 and v5 now have built in support for configuration management which eliminates the need for an external utility Also LTM v4 and v5...

Страница 35: ...1 5282 35 of 36 Dimensions 38 2 mm 0 5 mm 43 0 mm 1 0 mm 83 0 mm 0 5 mm 97 0 mm 0 5 mm Figure 5 Case dimensions for the eSynC 3U E PE 2UE P2UE vc3U vc2UE vc1U and vcE 38 2 mm 0 5 mm 43 0 mm 1 0 mm 127...

Страница 36: ...l 1 416 674 5942 www lavalink com Canada M9W 1L2 Toll Free US Canada 800 241 5282 36 of 36 Technical Support LAVA Technical support is open from 9 00 am to 5 00 pm Monday through Friday EST Telephone...

Отзывы: