LAVA Computer MFG Inc. eSynC Product Family - Reference Manual – C03
2 Vulcan St. Toronto, ON
Tel: +1 416 674-5942
www.lavalink.com
Canada, M9W 1L2
Toll Free (US & Canada): 800 241-5282
29 of 36
permit-ltm-icon=x
This command determines if the LTM Notification Icon is visible or transparent.
A 1 enables the LTM icon. This is the default.
A 0 disables the icon, which is made transparent.
It is not possible to eliminate the icon. The notification text is always present.
This feature was added in LTM v2.03.
log-file-rate=x
The number of minutes between updates of the diagnostic log file.
The log file records the battery level and several other relevant statistics.
A value of 0 results in updates only for changes in charge direction.
The permitted range is 0 to 1440.
The default is 0.
log-file-limit=x
The maximum size of the diagnostic log file.
The value is in units of 1000000.
The permitted range is 0 to 100.
A 0 disables logging.
The default is 0.
user-debug=x
This command enables a set of Toast based status messages suitable for the user.
The messages report the general state of the LTM application and device.
The permitted range is 0 to 3. The default is 1.
Level
Messages
Comments
0
No status messages
1
“LTM - controller attached”
The device has detected the eSynC board.
1
“LTM - controller running”
The LTM application has started to operate.
1
“LTM - controller detached”
The eSynC has disconnected from
the device.
1
“LTM - brightness update”
The LTM application has updated the
device screen brightness.
1
“LTM – inhibit in effect”
The LTM application was not allowed to run as
“ltm-inhibit=1” is set in the configuration file.
2
“LTM - charging nn%”
The device battery is charging.
The current battery level is “nn” percent.
2
“LTM - discharging nn%”
The device battery is discharging.
The current battery level is “nn” percent.
3
“LTM - PASS #nn”
The pass number “nn” increments each
time the LTM application runs.
Note: Each level includes the messages of the lower levels.