background image

14

CARE AND MAINTENANCE

 Gas odor with extreme yellow tipping of flame.
 Heater does NOT reach the desired temperature.
 Heater glow is excessively uneven.
 Heater makes popping noises.
 Spiders and insects can nest in burner or orifices. This dangerous condition can damage heater and
render it unsafe for use. Clean burner holes by using a heavy-duty pipe cleaner. Compressed air may 
help clear away smaller particles.
 Carbon deposits may create a fire hazard. Disassembly the reflector, unscrew the reflector spacer,
take off the screen, take down one side of protective guards. Then take the glass tube from the heater 
and wash and clear. After that assembly the glass tube and the rest of parts.

Note: 

In a salt-air environment (such as near an ocean), corrosion occurs more quickly than normal. 

Frequently check for corroded areas and repair them promptly.

 TIP:
 Use high-quality automobile wax to help maintain the appearance of 
 your heater. Apply to exterior surfaces from the pole down. Do not
 apply to emitter screen or domes.

Storage

Between uses:
 Turn Control Knob OFF.
 Disconnect LP cylinder.
 Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, 
sleet, hail, snow, dust and debris).
 If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.

Note: 

Wait until heater is cool before covering.

During periods of extended inactivity or when transporting:

 Turn Control Knob OFF.
 Disconnect LP cylinder and move to a secure, well-ventilated location outdoors.
 Store heater upright in an area sheltered from direct contact with inclement weather (such as rain, 
sleet, hail, snow, dust and debris).
 If desired, cover heater to protect exterior surfaces and to help prevent build-up in air passages.
Never leave LP cylinder exposed to direct sunlight or excessive heat.

Note: Wait until heater is cool before covering.

Service

Only a qualified service person should repair gas passages and associated components.

Caution

: Always allow heater to cool before attempting service.

Содержание MINI LAVA

Страница 1: ...For sales inquiries contact Sylvane at 1 800 934 9194 If you have service questions contact Lava Heat at 1 888 779 5282 ...

Страница 2: ... other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment WARNING For Outdoor Use Only WARNING WARNING...

Страница 3: ...1 B Mesh Reflector Damper Support Protective Guard 1 C Damper D Support E Protective Guard F Glass Tube 1 4 4 1 G 1 H 3 I Front Panel Bottom plate Control Box Assy Side Panel 1 J 1 A C D E Mesh B Glass Tube F Control Box Assy G Side Panel H Front Panel I Bottom plate J ...

Страница 4: ... caution demanded will reduce the possibilities of personal injury or property damage The following symbols shown below are used extensively throughout this manual Always heed these precautions as they are essential when using any mechanical or fueled equipment DANGER DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury FOR YOUR SAFE...

Страница 5: ... heat producing products for specific uses Your local authorities can advise you about these If no local codes exist follow National Fuel Gas Code ANS Z223 1 In Canada installation must conform to local codes If no local codes exist follow the current National standards of CANADA CAN CGA B 149 2 DANGER WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of th...

Страница 6: ...tore or use propane gas in compliance with local ordinances and codes or with ANS NFPA 58 Turn off propane when not in use WARNING Alert children and adults to the hazards of high surface temperatures Stay away from these surfaces to avoid burning skin or igniting clothing Carefully supervise young children when in the vicinity of the heater Do not hang clothing or any other flammable materials fr...

Страница 7: ...te a couple of assembly procedures to make the appliance operational Ensure all transit protection is removed 2 Keep the front panel open Rotate regulator toward opening in housing Line up threads on gas cylinder with those on the regulator Insert and rotate cylinder clockwise until tight ...

Страница 8: ... B149 2 Certain materials or items when stored under the heater will be subjected to radiant heat and could be seriously damaged Use a only a cylinder marked propane A dented rusted or damaged propane cylinder may be hazardous and should be checked by your cylinder supplier Never use a propane cylinder with a damaged valve connection The propane cylinder must be constructed and marked in accordanc...

Страница 9: ...wo side walls These side walls may be parallel as in a breezeway or at right angles to each other c Within a partial enclosure which includes an overhead cover and three side walls as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open Use a replacement pressure regulator specified by the appliance manufacturer Use the pressure regulator and hose assembly su...

Страница 10: ...ter The soap solution can be applied to hoses and connections with a spray bottle brush or rag 2 Make sure that the safety control valve is in the OFF position 3 Turn the cylinder valve ON and check for soap bubbles forming on and around connections and hoses If bubbles appear there is a leak present 4 If a leak is present remove the gas cylinder immediately tighten any leaking fittings replace th...

Страница 11: ...hly inspected before each use and by a qualified service person at least annually If relighting a hot heater always wait at least 5 minutes 2 Inspect the hose assembly for evidence of excessive abrasion cuts or wear Suspected areas should be leak tested If the hose leaks it must be replaced prior to operation Only use the replacement hose assembly specified by manufacturer Lighting Note This heate...

Страница 12: ...sed and a waiting period of at least 5 minutes should pass before attempting to light If you experience any ignition problem please consult Troubleshooting on page 14 Caution Avoid inhaling fumes emitted from the heater s first use Smoke and odor from the burning of oils used in manufacturing will appear Both smoke and odor will dissipate after approximately 30 minutes The heater should NOT produc...

Страница 13: ...ns are secure and do not leak 5 Wind velocity is below 10 mph 6 Unit will operate at reduced efficiency below 40 F 7 Heater is outdoors outside any enclosure 8 There is adequate fresh air ventilation When heater is ON The flame should be blue with straight yellow tops If excessive yellow flame is detected turn off heater and consult Troubleshooting on page 14 Re lighting Note For your safety contr...

Страница 14: ...n 21 More frequent cleaning may be required as necessary It is imperative that control compartment burner and circulating air passageways of the heater be kept clean After Operation 1 Gas control is in OFF position 2 Gas Tank valve is OFF 3 Disconnect Gas line WARNING FOR YOUR SAFETY Do NOT touch or move heater for at least 45 minutes after use Reflector is hot to the touch Allow reflector to cool...

Страница 15: ...nce of your heater Apply to exterior surfaces from the pole down Do not apply to emitter screen or domes Storage Between uses Turn Control Knob OFF Disconnect LP cylinder Store heater upright in an area sheltered from direct contact with inclement weather such as rain sleet hail snow dust and debris If desired cover heater to protect exterior surfaces and to help prevent build up in air passages N...

Страница 16: ...blockage Clean reflector and burner screen Outdoor temperature is less than 40ºF and tank is less than 1 4 full Turn cylinder valve OFF and replace cylinder Use a full cylinder Turn control knob to ON Dirt built up around pilot Connection between gas valve and pilot assembly is loose Thermocouple is not operating correctly Clean or replace orifice or pilot tube Open gas line and bleed it pressing ...

Страница 17: ...purchaser only and excludes industrial commercial or business use of the product product damage due to shipment or failure which results from alteration product abuse or product misuse whether performed by a contractor service company or consumer We will not be responsible for labor charges and or damage incurred in installation repair or replace ment nor for incidental or consequential damage LAV...

Страница 18: ......

Страница 19: ...For sales inquiries contact Sylvane at 1 800 934 9194 If you have service questions contact Lava Heat at 1 888 779 5282 ...

Отзывы: