@2012.11-V1.1
Aviator X2
Page 15 of 15
²
Thoroughly Cleaning ( Suitable for cleaning after 60 hours’ operation)
1.
Take the main body apart with the water tank.
1.1 Loosen the 4 butterfly screws on the plate inside the tank
(Refer to the Installation Instruction—Step 3 / Picture 4)
1.2 Take the main body apart with the water tank; take out the submersible pump
and water level sensor (Refer to Installation Instruction—Step 2 / Picture 2)
2.
Clean the water tank
Wash the Water Tank inwall with towels or soft brush; open the drain valve
to drain off the waste water; then wash it again with fresh water and the right
amount of cleanser; close the drain valve.
3
、
Refix the submersible pump and water level sensor; Connect the main body with
the water tank. (Refer to the Installation Instruction—Step 2 / Picture 3)
Note: Please make sure the floater should face the bottom. Otherwise the Level
Sensor will not work.
Inspection and Maintenance in Daily Use
1
、
Make sure the machine is connect to the Electricity Leakage protector, and the
earthing wire is connected to specified earthing system of the construction.
2
、
Before running the product, please check if there any damage or jamming with the
Guard Nets, or if the Impeller rotates smoothly.
3
、
Pay attention to waterproof and damp-proof.
4
、
When the Misting Air Cooler is not in the need of using for a long time,
5
、
4.1 Power should be cut.
6
、
4.2 The Guard Net, Impeller and body should be clean regularly.
7
、
4.3 Use specialized protective cover to prevent the damage of rain and dust.
Drain Valve