  Attentions: 

Please carefully read the following items:

 

Caution

The product MUST be connected to the power with leakage protection device. 

¨

 

Make sure firmly plugged 

 

 

¨

 

Be sure not to take off the plug 

while operating. 

 

 

 

 

 

Otherwise,  it  may  cause  electric 

shock or fire hazard. 

¨

 

Be  sure  not  to  damage  or  use 

unspecified power line. 

 

 

 

 

 

Otherwise,  it  may  cause  electric 

shock or fire hazard. 

¨

 

Please do not use the same 

socket with other equipment, or 

use extended cable. 

 
 
 
 

Otherwise,  it  may  cause  electric 

shock or fire hazard.   

 

¨

 

Be  sure  not  to  operate  the 

product with a wet hand. 

 

 

 

 

 

Otherwise,  it  may  cause  electric 

shock or fire hazard. 

¨

 

Don’t  take  off  the  plug  by 

pulling the power cord. 

 

 

 

 

 

Otherwise,  it  may  cause  electric 

shock or fire hazard. 

¨

 

Power off while adding water or 

cleaning the product. 

 

¨

 

The  voltage  used  can  be 

fluctuated  within  the  rated 

voltage  range.  Too  low  or  too 

high  voltage  may  damage  the 

motor. 

 

Power  off the product immediately 

once there are some abnormalities. 

 

 

 

     

 

 

Otherwise,  it  may  cause 

electric shock or fire hazard 

Содержание Aviator X2

Страница 1: ...ELECTRICCOMMERCIALGRADEPATIOCOOLER INSTRUCTIONSMANUAL ...

Страница 2: ... Ø Outline Drawing 3 Ø Wiring Diagram 4 Ø Installation Instructions 5 8 Ø Checking after Installation 8 Ø Trial Operation 9 10 Ø Attentions 11 12 Ø Common Malfunction Analysis and Maintenance 13 15 PICTURES ARE ONLY FOR INFORMATION TAKE MATERIAL OBJECT AS STANDARD ...

Страница 3: ...relative humidity reduce dust and purify air which makes a comfortable living working space The internal structure uses independent control devices and human intelligent warning protection system which separates electricity from water so as to eliminate safety risk Featured by non clogged misting system low energy consumption low pollution low noise low heat low carbon our products are widely used...

Страница 4: ... 2012 11 V1 1 Aviator X2 Page 4 of 15 Wiring Diagram Aviator X2 Aviator X4 ...

Страница 5: ...apart from the water supply please screw on the choke plug so as to avoid water leakage Picture 1 Remarks As the Water Tank is very heavy please be careful to avoid scratches of Water Tank or hurt of the assemblers 2 Fasten the Submersible Pump and Level Sensor Turn the Water Tank with installed wheels back and fasten the Submersible Pump and Level Sensor inside the Water Tank see Picture 2 Pictur...

Страница 6: ... Main Part and Water Tank Lock the 4 wheels and then place the Main Part on the Water Tank Picture 3 Picture 3 Rip off the protective coating of the Electricity Box on the Main Part take it out and then fasten the two connecting plate together with 4 M6X20 Butterfly screws see Picture 4 Picture 4 4 Connect the Electric Wire of Submersible Pump and Level Sensor When installing please align the 2 ar...

Страница 7: ...evel Sensor with the corresponding interface from the Electricity Box and fasten the Nuts see Picture 6 Picture 6 Remarks For ensure waterproof please make sure the rubber ring is inside the Electric Wire interface Besides interfaces of Submersible Pump and Level Sensor are two pins but different from each other For avoiding any destroying of interfaces please don t insert them violently 5 Fix Ele...

Страница 8: ...aterial like batten Check the normal rotation and isolation between the blades and casing 3 Before using check whether the voltage and frequency on the nameplate match those in use Then add water into the tank manual inflowing or automatic inflowing Check whether there is any leakage of the water tank 4 Power on the product to see its operation Switch on each speed check whether it sounds abnormal...

Страница 9: ...n it reaches the highest level Automatic Adding Water Please remove the choke plug and then connect the weaved hose at the bottom of the tank to water supply turn on the faucet and begin adding water there is a water level sensor inside the tank When the tank is full it will stop inflowing When water reaches the lowest level it would restart inflowing automatically When the weaved pipe is apart fr...

Страница 10: ...uld begin blowing Observe whether the fan blows normally by switching the speed 1 2 3 2 Press the button MIST the centrifugal disc would begin rotating and producing mist View whether there is any difference of the mist quantity while rotating the Mist regulating switch from Min to Max Swaying Switch Misting Switch Blowing Switch ...

Страница 11: ... not use the same socket with other equipment or use extended cable Otherwise it may cause electric shock or fire hazard Be sure not to operate the product with a wet hand Otherwise it may cause electric shock or fire hazard Don t take off the plug by pulling the power cord Otherwise it may cause electric shock or fire hazard Power off while adding water or cleaning the product The voltage used ca...

Страница 12: ...ly by the fan Otherwise they may get harm Please not to let the product blow directly to stove Please do not connect the product to potable water mains Water Pressure Range 0 1 0 45 M Pa Make sure the water tank is cleaned before using For long time no using the product please drain off the tank so as to avoid the growth of bacteria Otherwise accumulative dirt and likely to cause fever or fire acc...

Страница 13: ...oo low measured by professionals Proper use of the timer refer to product with remote control It can mist but fail to blow air Twirl the impeller to check if the blade is stuck Check if each switch works Is male female plug of fan motor connected properly It can blow air but fail to spray mist Mist regulating switch is on or off MIST switch is on or off The tank is with water and reaches the lowes...

Страница 14: ...adjusting the switches please close the cover of the control box and tighten the screws as shown so as to prevent erosion of rainwater or PVC panel aging caused by sun exposure Water Tank Cleaning Simple cleaning Suitable for the cleaning of each use Rotate the two nuts on the control panel push the panel inwards clean the inner tank with long handled brush then open the drain valve to drain off t...

Страница 15: ...bmersible pump and water level sensor Connect the main body with the water tank Refer to the Installation Instruction Step 2 Picture 3 Note Please make sure the floater should face the bottom Otherwise the Level Sensor will not work Inspection and Maintenance in Daily Use 1 Make sure the machine is connect to the Electricity Leakage protector and the earthing wire is connected to specified earthin...

Страница 16: ...purchaser only and excludes industrial commercial or business use of the product product damage due to shipment or failure which results from alteration product abuse or product misuse whether performed by a contractor service company or consumer We will not be responsible for labor charges and or damage incurred in installation repair or replace ment nor for incidental or consequential damage LAV...

Страница 17: ...engineered high quality products for all to use and enjoy for years to come Lava Aire was originally founded by lead designer and chief engi neer Mr JR Zioni in Modena Italy in 1997 Today Lava Aire Italia has expanded to the USA and offers well over 100 innovative heating cooling and home appliance products worldwide We encourage you to visit our website www LavaAire com to get a detailed view of ...

Отзывы: