Signal Filtering / Averaging
You can adjust the filtering time constant to reduce the effect of noise or instability on your
input signal. A larger FIL value will give a more stable display, but the response to signal
changes will be slower.
Because your output options, such as analogue output, alarm relays and serial output are
all derived from the displayed value, they will respond at the same rate as the filtered
display.
See also Filter Jump setting if your signal is particularly noisy and you cannot get sufficient
smoothing with this filter.
This meter also includes an active filter for removing the effects of vibration. It is shipped
with the filter enabled for maximum stability. You can move a push-on jumper switch to
change the filter response to maximum speed if you wish. See below.