20
21
SCALE FILTER REPLACEMENT
The scale filter shall be replaced when its granules
become completely brown.
• Remove the water tank from the steam generator.
Remove water tank covers. Remove the scale filter.
The scale filter can be disposed of with
the household waste.
• Wash the filter compartment. Install a new scale
filter into the water tank.
• Fill the tank with tap water.
• Filtered water shall reach the maximum level
(MAX mark). Place the tank back onto the steam
generator.
Plastic parts of the water tank can be washed
in the dishwasher.
STEAM GENERATOR WASHING
In order to extend the term of effective operation
of the device and in order to avoid scale marks –
rinse the steam generator regularly.
Rinse parts with water only. Do not apply descaling
agents or other chemicals.
• Follow the steps outlined in the «Device
preparation» section for flushing.
• Repeat stated steps until all scaling elements
disappear and are not contained in water leaving
the steam generator. Contact the service centre
if water does not flow out through the drain hole.
• Install both covers back after all water runs out.
Remove the drained water. Put the filter back into
the water tank, close covers and place the tank
onto the steam generator.
STORAGE
The device is recommended to be stored
in the assembled condition in a cool dry place,
isolated from places of storage of acids and bases,
at the temperature from 5 to 30 °C and relative
humidity of 65 %.
The iron supply kit includes a silicone stand
for ease of use. If necessary, take a break
in operation and place the iron on the stand
horizontally.
TROUBLESHOOTING
Problem
Possible cause
Troubleshooting
Humming in the course of steam release
from the iron
Device vibration.
Presence of such sound is normal for a new device, it will disappear with further
application.
Crackling in the course of device
operation
Heating is activated for the device not filled
with water.
Fill the water tank.
The iron does not release steam.
Pressure drop
• Empty the steam generator.
• The device is turned off.
• The power plug was removed from
a corresponding outlet.
• Fill the water tank.
• Press the instrument’s main switch button.
• Connect the power plug.
The soleplate is leaking
• The device has not been washed for a long time.
• The steam generator was rinsed not with water,
but with another means.
• Rinse the steam generator until scaling elements disappear from water.
• Contact the customer service.
The iron does not heat up
• The power plug was removed from
a corresponding outlet.
• The device is turned off.
• Connect the power plug.
• Turn the device on.
The fan makes no sounds
The fan plug has not been connected.
Connect the fan plug.
The pointed end of the table gets wet
in the storage position
Condensate in the table body.
• Leave the device open until the moisture evaporates fully.
• Apply less steam. Read contents of the manual, paragraph «STEAMING PRINCIPLE».