12 

 

Press OPT key to start 
 
Step1 
Rotate the gas nozzle to 12 o’clock. 
Press ENTER key to memorize the point .Mark with a chalk a 
reference mark on the tire 
 
 
Step2 
Remove the wheel from the balancer using a tire changer. Align 
the nozzle and the mark by rotating the tire on the rim by 180 
degrees. 
 
 
 
Step3 
Replace the wheel on the balancer and rotate the gas nozzle to 12 
o’clock again. Press “ENTER” key to memorize 
 
 
Step4  
Press START key to start OPT measurement. 
After measurement, mark with chalk again on the tire the marked 
point indicated on the screen. 
Using the changer to assemble until the

 new mark

 and the gas 

nozzle coincide. Now the value displayed is the

 rest value after 

optimization

 .On this point add 10g counterweight. 

 
 
 
 
Press ENTER to end optimization 

 

10. Motorcycle Mode 

Motorcycle mode is the same as standard dynamic mode except that it needs special motorcycle fixtures and extending arms.   

Содержание KWB-511

Страница 1: ...V1 00 000 2012 08 20...

Страница 2: ...request written permission to use Materials on this manual for purposes or for all other questions relating to this manual Copyright Information Copyright 2012 by LAUNCH TECH CO LTD All rights reserve...

Страница 3: ...y This manual instruction is suitable for wheel balancer KWB 511 This unit is made for the purpose of persons who have special techniques and certifications Safety Instructions z Make sure all operato...

Страница 4: ...ol Unit 4 Operating Instructions 5 1 Self check 5 2 Installing Wheel 5 3 Wheel Parameters Input 5 4 Choose balance modes 6 5 Standard Dynamic Mode 7 6 Static Mode 7 7 ALU 1 ALU 3 Modes 8 8 ALU S Mode...

Страница 5: ...ody 2 Functions z Dynamic Mode z Static Mode z Standard ALU1 ALU2 ALU3 Mode z ALUS Mode z OPT OPTIMIZATION mode z Unit Conversion in Different Countries Areas g oz mm inch z Mechanical sensor arm z Se...

Страница 6: ...g 0 1 oz z Noise 70dB z Net Weight 95kg z Gross Weight 116kg z Working Environment Temperature 20 50 Humidity 85 z Package dimensions 900 700 1170mm 4 Packing List SN Description Quantity Picture 1 Wh...

Страница 7: ...LAUNCH KWB 511 Wheel Balancer user s manual 3 8 Pliers 1 pc 9 Thread and bolt 1kit 10 socket head wrench 1 kit 11 hanger 3 pc 12 Standard Weight 1 pc 13 Quick nut and bowl 1 kit...

Страница 8: ...outside unbalance display window F outside unbalance point G standard dynamic mode indicator H static mode indicator I ALU mode indicator J ALUS mode indicator K OPT indicator L mm inch indicator M Mo...

Страница 9: ...and 5 The method shown in figure 5 is preferable because it approximates to installing wheel on a real car Fig4 Fig5 3 Wheel Parameters Input Unlike ALU S which needs 4 parameters other modes need 3...

Страница 10: ...input state In the state of D value input press to convert mm and inch 4 Choose balance modes The default mode of this equipment is standard dynamic mode Choose other mode by pressing keys DYN STA ALU...

Страница 11: ...is displayed Rotate the wheel clamp a counterweight of the displayed value eg 70g on the outside correction position Keep rotating clamp a counterweight of the displayed value eg 40g on the inside co...

Страница 12: ...ALU 1 ALU 3 Modes ALU1 3 mode refers to 3 counterweight sticking modes reduced according to the shapes and sizes of most rims Refer to Fig12 A special purpose gauge can be used to assist in sticking c...

Страница 13: ...o get ready for being stuck 2 ALU S Mode Operation Mount the wheel and collect parameters After collecting close the guard press START to measure The process is the same as that of standard dynamic mo...

Страница 14: ...LAUNCH KWB 511 Wheel Balancer user s manual 10 Fig15...

Страница 15: ...Medial end of lead paste Fig16 Note The KWB 511 mechanical sensor arm can only locate the 12 o clock position it will return to the measurement interface if at any other position So it is better to lo...

Страница 16: ...alancer and rotate the gas nozzle to 12 o clock again Press ENTER key to memorize Step4 Press START key to start OPT measurement After measurement mark with chalk again on the tire the marked point in...

Страница 17: ...ual 13 Fig17 Fig18 Setting programs 1 System setting System setting refer to Fig19 is used to set options such as the application control state the commonly used units of this equipment and so on Ways...

Страница 18: ...equipments measurement errors caused by total loss from use parts ageing and replacing or strong impact Calibration procedures include unbalance calibration Press or key to exit calibration program C...

Страница 19: ...ibration of rotation for the first time End rotation prompt placing a counterweight of 100g at 12 o clock outside of rim Press calibration of rotation for the second time Press complete correction of...

Страница 20: ...ever because the laws and regulations of safety protection in different countries are not completely the same we suggest not turning off the guard function option Err 02 Prompt is given and measuremen...

Страница 21: ...LAUNCH KWB 511 Wheel Balancer user s manual 17 CE Declaration of Conformity...

Страница 22: ...LAUNCH to any affirmation representation or warranty concerning LAUNCH automotive meters except as stated herein Disclaimer THE ABOVE WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED INC...

Отзывы:

Похожие инструкции для KWB-511