- 38 -
Press PRINT to print the number of pieces on the scale (see section
PRINTING EXAMPLES
).
In piece counter mode you can:
-
set weight to zero for small variations (press
0
and confirm with ENTER);
-
set semi-automatic tare (press TARE);
-
do a new sampling:
▫
WDESK – WINOX: press START for 3 seconds,
appears, press ENTER, set number of
pieces on scale and confirm with ENTER;
▫
WTAB: press MODE,
appears, press ENTER, set number of pieces on scale and
confirm with ENTER;
-
WDESK – WINOX: to exit piece counter mode and return to standard operations,
press START for 3 seconds,
appears; press ESC, select the
operating
mode and confirm with ENTER. If no setpoint is enabled,you can do a new sampling
or return to standard operations also by pressing MENU.
-
WTAB: to exit piece counter mode and return to standard operations, press MODE,
appears; press ESC, select the
operating mode and confirm with ENTER.
ENABLING SETPOINT
Setpoint can be used to stop automatic loading of pieces on the weighing system.
WTAB: setpoint are always enabled.
WDESK – WINOX: proceed as follow to enable setpoint:
-
(default)
:
setpoint disabled;
-
:
setpoint enabled;
Setpoint 1 and 2 switch based on number of pieces, the others always switch on weight.
After enabling the setpoint, key operations to access menus vary as follows:
-
Press MENU to access setpoint settings;
-
Press START for 3 seconds for new sampling or to change operating mode.