- 23 -
scale value set.
FILTER VALUE
Response times
[ms]
Display and serial port refresh
frequency
[Hz]
0 12
300
1 150
100
2 260
50
3 425
25
4 (default)
850
12.5
5 1700
12.5
6 2500
12.5
7 4000
10
8 6000
10
9 7000
5
ZERO PARAMETERS
RESETTABLE WEIGHT SETTING FOR SMALL WEIGHT CHANGES
(from 0 to max full scale; default: 300; considered decimals: 300 – 30.0 – 3.00 – 0.300): this
parameter indicates the maximum weight value resettable by external contact, keypad or serial
protocol.
AUTOMATIC ZERO SETTING AT POWER-ON
(from 0 to max 20% of full scale; default: 0): If at switch-on the weight value is lower than
the value set in this parameter and does not exceed the
value, the weight is reset. To
disable this function, set 0.
ZERO TRACKING
(from 1 to 5, default:
): When the weight value is stable and, after a second, it
deviates from zero by a figure in divisions smaller or equal to the figure in divisions set in this
parameter, the weight is set to zero. To disable this function, set
.
Example:
if the parameter
is set to 5 and
is set to 2, the weight will be automatically
set to zero for variations smaller than or equal to 10 (
x
).