- 35 -
10.
The system ends the batching (opening of the CYCLE END contact) only after verifying that the
safe emptying time has elapsed (
);
11.
Only if
=
: the instrument waits for data recording on PC, before being available for a
new batching.
If several batching cycles have been set the instrument starts a new cycle.
During the batching, if
=
and the weight reaches the minimum weight (
), the
instrument pause the batching and starts the AUTOMATIC LOADING of the plant; at the end it
return in pause condition, press ENTER or close the START input to resume the batching or press
STOP to cancel it.
AUTOMATIC LOADING
The AUTOMATIC LOADING phase allows the product loading into the weighed structure by the
closing of the LOAD contact; in this phase the instrument displays the
message alternated
with the weight. Set the minimum (
) and the maximum weight (
), to enable this function.
The AUTOMATIC LOADING can be started in two different ways:
-
Manually by the operator (closing the IN3 input, if set as
);
-
Automatically by the instrument (only if at the end of the batching, the weight is lower than
the minimum weight);
The AUTOMATIC LOADING ends if one of the following conditions occurs:
-
The weight reaches the maximum weight value (
);
-
The operator closes again the IN3 input, if set as
;
-
The operator press the STOP key.
If you want to manually start an AUTOMATIC LOADING during the batching, prior to start it pause
the batching with the STOP key (opening of SET and PRESET contacts); at the end of the
AUTOMATIC LOADING, the instrument is paused; press ENTER to resume the batching or STOP
to cancel it.
WARNING:
Only if BIG BAG UNLOADING has been enabled (
=
) and if during the
batching the weight reaches the minimum weight (
), the instrument:
-
waits for the safe emptying time (
);
-
pauses the batching (opening of the SET and PRESET contacts);
-
starts the AUTOMATIC LOADING phase (closing of the LOAD contact).
The display shows the
prompt alternated with the weight and the operator must replace the
big bag (or the container) of the product. At the end of the AUTOMATIC LOADING phase, the
instrument is paused and waits for the operator intervention; press ENTER to resume the batching
or STOP to cancel it.