- 8 -
INTRODUCTION TO THE OPERATION
The instrument is able to load automatically a settable amount of product on the weighing structure,
driving the batching organ (including two-speed) through the PRESET and SET contacts.
The instrument has the following features:
-
Maximum 99 settable formulas (see section
FORMULAS PROGRAMMING
);
-
Batching resume after blackout (see section
RESUME BATCHING AFTER A POWER CUT
);
-
Automatic fall calculation (see section
FALL
);
-
Autotare at batching start (see section
AUTOTARE
);
-
Tolerance error control (see section
TOLERANCE
);
-
Precision batching through slow function (see section
SLOW
);
-
Precision batching through tapping function (see section
TAPPING FUNCTION
);
-
Consumption storage (see section
CONSUMPTION
);
-
Print of batching data (see section
PRINT AT CYCLE END
);
-
Alarm contact (see section
ALARM RELAY CLOSURE
);
BATCHING START:
-
via keypad, setting formula and cycle number to be performed;
-
via external contact (see section
BATCHING START FROM EXTERNAL CONTACT
).
For further information on the batching sequence, see section
BATCHING
.
CONSUMPTION STORAGE:
The instrument, at the end of every batching, stores the consumed amount for each formula.
Consumption value can be viewed directly on instrument display in standby mode.
INSTRUMENT CALIBRATION:
The instrument calibration can be performed both with THEORETICAL CALIBRATION, setting the
instrument full scale and the load cells sensitivity (see section
THEORETICAL CALIBRATION
), and
with REAL CALIBRATION through SAMPLE WEIGHT (see section
REAL CALIBRATION (WITH
SAMPLE WEIGHTS)
).
ALARM MANAGEMENT
:
If an alarm occurs during the batching, the instrument shows the alarm on the display, closes the
related contact (if enable) and waits for operator intervention to abort or continue the batching.