- 19 -
AUTOMATIC DIAGNOSTICS OF LOAD DISTRIBUTION
Only use this function in systems where load distribution can be repeated with each
change of weight (for example: liquid weighing).
-
(
/
; default:
): it enables load diagnostics.
-
: it displays the active channels status (weight, load percentage on each channel,
enabled channels and/or channels in error).
-
: it displays stored load distributions (weight, load percentage on each channel).
-
: it deletes stored load distributions; confirmation is requested (
),press ENTER to
proceed or press ESC to cancel.
-
(default: 5.0): difference between the current and stored percentage beyond which the
alarm is triggered.
-
(
/
; default:
): it enables diagnostics on zero.
-
(default: 5.0): difference between the current and stored percentage beyond which the
alarm is triggered.
-
: it displays current load distribution on zero and the one previously stored (weigh, load
percentage on each channel).
Load diagnostics: the instrument, with stable weight, calculates and stores the load percentage on
each channel. If under normal operation the load percentage error is higher than the value set in
parameter
, the display shows the
alarm alternated with the weight; the alarm
remains active also upon instrument power-off, press ENTER to cancel.
Diagnostics on zero: if with unloaded system the load percentage error is higher than the value set
in parameter
, the display shows the
alarm alternated with the weight; the alarm
remains active also upon instrument power-off, press ENTER to cancel.
Diagnostics on zero is only available if it has been enabled during the installation.
Example of current load distribution display: the top of the display
shows the weight on the scale; the bottom shows the load
percentage on each active channel.
This screen can also be accessed directly from the weight display
by pressing the TEST key.
+