Grounding Instructions
The plug must be inserted into an outlet that is properly
installed and grounded. ln the event of an electrical short
circuit, grounding reduces the risk of electric shock. The
electrical outlet, which must be a 100-240V~, 50/60Hz,
and at least a 15-Amp grounded outlet, should be located
on the wall within reach of the unit’s power cord. A ground
fault interrupter residual current device (RCD) should be
installed on the circuit supplying power to each local
regulation.
Danger
- lmproper use of the grounding plug
can result in a risk of electric shock. Repair or
replacement of cord or plug should be done by
authorized personel. Make sure grounding is
correct. Do not use extension cable.
A
The WC must be installed in the protection
volume 3 of the bathroom. Neither component
or connection of the WC must be installed out of
this area. No electrical device must be introduced
inside the WC. This product must be installed
by qualified personnel, in accordance with the
national current regulation.
(cm)
Volume
1
Volume
0
Volume
2
Volume
3
60
60
225
10
0
25
0
300
~195
405
66
0
40
0
12
5
~230
16
5
305
178
68
2400
25A IDn 0.03A
220-240V~
50/60Hz
1300W
15A