2.8 Final Check
2.9 Test Run
WARNING
After installation, make sure that all the components, fixture, and thumbscrews are tightly in
their places. Make sure that no impurities fall into the ice storage container.
WARNING
Icemaker is factory-adjusted. In general, no additional setting is required after installing the
product. In case of random modification, it may cause adverse influence on safety, function,
component lifespan, and warranty period. Warranty is not included in the setting and
maintenance process explained in this manual.
(1) Is ambient temperature of the installation area within the allowed range 45-100°F(7-37°C)?
(2) Is temperature of water supplied in the installation area within the allowed range 45-90°F (7-32°C)?
(3) Are all the packing materials such as packing box, inside tape, and other materials removed
completely?
(4) Is there an enough clearance from the icemaker for smooth air circulation?
(5) Is ice scoop placed in the right place?
(6) Is icemaker leveled on the floor?
(7) Is the product located indoor?
(8) Is the power supply to the icemaker installed properly?
(9) Is water supply pipe to the product properly connected?
(10) Is drain system properly connected?
(11) Is water pressure qualified (30 ~100 psig)(206.8-689.4 kPa)?
(12) Any leakage found in any pipes?
(13) Are all the components, fixtures, and thumbscrew fixed tightly?
(14) Have you informed to the customers about the product manual, how to use, and interval for
changing main components?
(15) Have you provided information on selling points and service center to the customer?
(1) Open the shut off valve in the water supply line.
(2) Press "Power" button for 2 seconds to operate the icemaker.
(3) Water tank is filled with water through the water supply valve.
(4) After water is filled, it turns into harvesting cycle and control board shows “2.00.”
(5) After this, it turns into freezing cycle and control board shows “3.00.”
(6) About 3 minutes after freezing cycle, press “Power” button for 2 seconds to stop the machine.
(7)
①
150A : Disconnect ’Hose Drain Joint’ connected to‘ Water Tank’ to drain remaining water.
②
250A : Push ‘Wash’ button to drain remaining water.
(8)
①
150A : Reconnect ‘Hose Drain Joint’ once remaining water is completely drained.
②
250A :Turn off the machine when ‘Add’ is appeared on the control panel.
(9) Press “Wash”button to release water inside the water tank.
(10) Unplug the power cord.
(11) Open the door and clean inside of the ice storage inside with neutral detergent.
(12) Wash thoroughly after cleansing.
(13) Operate the machine and check any leakage inside and outside the pipes.