WARNING
- Level sensor may not operate properly due to water condition or sediment inside of the
sensor.
For proper operation of Level sensor, clean the sediment inside of the sensor often.
- Level Sensor should be cleaned at least once a month.
(Recommended cleaning period can be shorter due to the condition of water.
4.3 Level Sensor Cleaning
1) Refer to “2.5 How to Remove Panel”, to separate the Ice Cover from body
2) In order to drain out water inside the cabinet completely, detach Pump Hose as shown in the mage.
3) Disassemble Level Sensor refer to “Front Cover” in the Removal and replacement chapter.
4) Separate the parts in order of Connector, Stopper, Float, and Body referring to image.
5) Wash contamination inside of Connector and Body.
6) Reassemble Level Sensor in reverse order.
7) Reassemble front panel.
Pump Hose
Body
Stopper
Level Sensor Connector
Float
Fig 7