background image

Page 

4

EC-2502

 

LASKOMEX PPUH

, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

Kaseta elektroniki

DATA:

EC-2502

ul. Nowa 20, 90-031 •ód•,

tel. (0-42) 672 44 00, fax 672 44 45,

e-mail: [email protected],

http://www.laskomex.com.pl

AC1

AC2

GP

VP

AC3

AC4

GZA

VZA

KZ

VZ

GZ

J3

-B

+B

GS’

VS’

14 V 

AC

0.8 

A

+7V

 0.5A

12 V 

AC

A

+13V

 0.8A

+12V

L-

L+

K6

K5

K4

K3

K2

K1

PR/CS

BALANS

MIKROFON

G•O•NIK

RESET

CP-2500

A/B

P2

BALANCE

MICROPHONE

LOUDSPEAKER

P1

P3

-      +

-      +

-      +

demagnetizing off

X

SW1

SW2

a)

b)

P2

P1

P3

J3

ZT1

ZT1

J3

B) Electromagnetic lock

A) Electro-catch

ZT1

ZT1

J3

demagnetizing on

J3

FUSE

Socket to connect ISD-02 interface

Electronic cassette EC-2502 can control electro-catch (by default setting). It is also a possibility to
control electromagnetic lock (or reverse
electro-catch). The selection of control method enables jumper ZT1.If electromagnetic lock is used
jumper should be put on joint J3 and operation frequency (parameter FrY) should be set on 0! (see
figure 2).In case electro-catch is used jumper should be removed from joint J3.

Figure 2: Selection of electro-catch or electromagnetic lock.

4. ADJUSTMENT

Elements of entry phone system are preliminarily adjusted and position of internal
potentiometers should not be changed without necessity.

Electronic cassette EC-2502 has the following adjustment elements (see dwg. 3):

 P1 - volume control in external panel loudspeaker
 P2 - volume control in uniphone loudspeaker (amplification of panel microphone)
 P3 - line balance responsible for the lack of acoustic interference

Figure 3: Control elements in electronic cassette

Additional there are potentiometers for control acoustic track:

 P4 - amplification of microphone track in external panel (potentiometer in external panel)

 P1 - amplification of microphone track in uniphone (potentiometer is in uniphone)

A detailed description of the regulation of electronic cassette EC-2502 is in the installation, service
and programming instruction of digital entry phone system CD-2502.

All manuals and user guides at all-guides.com

Содержание EC-2502

Страница 1: ...DIGITAL ENTRY PHONE SYSTEM INSTALLATION SERVICE AND PROGRAMMING MANUAL OF ELECTRONIC CASSETTE EC 2502 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...ion of testing the electro catch control frequency after changing the Fry parameter Increased entrance preview time after the entry of coded lock code Added keypad blocking function during RFID readin...

Страница 3: ...supply adapter is mounted supply from power network should be routed Electronic cassette casing is fixed to the base by means of two screws Wire ends from feeding transformer should be wound on the s...

Страница 4: ...t on joint J3 and operation frequency parameter FrY should be set on 0 see figure 2 In case electro catch is used jumper should be removed from joint J3 Figure 2 Selection of electro catch or electrom...

Страница 5: ...nt NbL 1 1 0 0 1 1 1 0 0 1 1 0 0 1 1 U H U H U H U H U H U U U U U H U H U H U H U H Sound signal of sign selected from the keyboard Multitone signaling of sign selected from the keyboard Duration of...

Страница 6: ...the apartment Addition of key with assigned to the apartment Addition of key on the selected item in memory Deleting the key Deleting the key assigned to the apartment Deleting the key recorded in the...

Страница 7: ...s configured as EC 2502 H after finishing of this operation the cassette will still operate in this mode Pushbutton RESET is used for momentary stopping the operation of a processor Its pressing makes...

Страница 8: ...nd supplier Subordinate entrances should be connected in such a way as if entry phone CD 2502 line L L was installed at the main entrance If CD 3100 is connected with CD 2501 mode with building number...

Страница 9: ...ne between cassette H and U KZ output of key switching on el catch if works as EC 2502H VZ electro catch supply L uniphone line if works as EC 2502U GZ mass of key switching on el catch LM master line...

Страница 10: ...n AC2 AC1 CP xxxx 12 V AC 1 A Brown Brown K6 K5 K4 K2 K3 K1 X GX GZ VZ KZ GZA VZA VP GP AC4 AC3 C C EC 2502 U 230 V AC 14 5 V AC 0 8 A White Brown AC2 AC1 CP xxxx 12 V AC 1 A AC4 AC3 Brown Brown L L K...

Страница 11: ...SY UTP LAN T11 XzTKMXpw Clamps Distance CP EC 15m 30m K1 K4 K1 K4 0 5mm 2x 0 5mm K2 K6 K2 K6 0 5mm 0 5mm K3 K3 3x 0 5mm 5x 0 5mm K5 K5 2x 0 5mm 2x 0 5mm X GX X GS 0 5mm 0 5mm Note In panels 250xxR GX...

Страница 12: ...nsiderably contributes to the protection of human health and life as well as protection of natural environment Return of packaging materials for the material recycling saves raw materials and reduces...

Отзывы: