background image

Page 

7

EC-2502

 

LASKOMEX PPUH

, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

X

SW1

SW2

P2

P1

P3

RESET

INIT

6. RESTORE THE INITIAL SETTINGS

NOTE!

Restoring the default settings results in the loss of information stored in EEPROM memory of
electronic cassette (changed codes of coded lock, numbers of electronic keys, individual settings
etc.). Prior to this operation one should get acquainted with the content of this chapter.

Restoring the default operation parameters for electronic cassette can be done in two ways: globally
(refers to parameters set by procedures P-1, P-2, P-5, P-6 and P-10) or selectively (default values
defined by individual procedures are restored).

Global restoration of default parameters. Reset of electronic cassette.

In order to restore default parameters of electronic cassette operation pushbutton INIT (SW2) should
be pressed and while still pressing it pushbutton RESET (SW1, see dwg. 2) should be pressed for
a while and released. After approx. 2 seconds pushbutton INIT (SW2) can be released, at that time
on the display of the external panel quickly changing digits will appear.
When the countdown visible on the display stops, all default settings will be restored in the cassette:
default codes of coded locks, code of installing specialist, main unit operation parameters defined
in procedures P-1, P-2, P-3 and P-5.

NOTE!

It pushbutton INIT after having initiated remains pushed in for longer than 10 s, electronic cassette
will start resetting all recorded iButton and/or RFID keys.

Operation mode of electronic cassette will not be changed i.e. if before restoring default settings the
cassette was configured as EC-2502/H, after finishing of this operation the cassette will still operate
in this mode.
Pushbutton RESET is used for momentary stopping the operation of a processor. Its pressing makes
that the processor stops working, while the release causes the operation resumption; the processor
starts the operation from the program beginning.
The pushbutton is used in the case of main unit hang-up (it does not react to key selection and
random signs appear on the display) and restoring default settings.
Pressing pushbutton INIT is information for the processor that the default settings should be restored
- main unit checks if this pushbutton was pressed just after switching on the supply or pressing and
releasing of RESET pushbutton. That is why the sequence of operations is important during restoring
the default values.

Figure 4: Position of pushbuttons INIT and RESET

Selective restoring of default settings of the entry phone system.

Enables restoring the default values of the selected parameters without change of other parameters.
This function is available for the installing specialist after entering the cassette programming mode
and does not require the direct access to entry phone electronic cassette.

 P-3-7 - Restoration of operation parameters and configuration of electronic cassette. Restores

default values of parameters in procedures P-1 and P-2.

 P-3-8 - Restores default values of coded lock codes and preset code the installing specialist.

If the code of the installing specialist was changed earlier it should be remembered to
change it again because quitting the programming mode will require entering the previous
code. If the installing specialist has forgotten the previous code he can read it from a
label on the cassette processor.

 P-3-9 - Restoring the default values of individual settings for apartments.

All manuals and user guides at all-guides.com

Содержание EC-2502

Страница 1: ...DIGITAL ENTRY PHONE SYSTEM INSTALLATION SERVICE AND PROGRAMMING MANUAL OF ELECTRONIC CASSETTE EC 2502 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 2: ...ion of testing the electro catch control frequency after changing the Fry parameter Increased entrance preview time after the entry of coded lock code Added keypad blocking function during RFID readin...

Страница 3: ...supply adapter is mounted supply from power network should be routed Electronic cassette casing is fixed to the base by means of two screws Wire ends from feeding transformer should be wound on the s...

Страница 4: ...t on joint J3 and operation frequency parameter FrY should be set on 0 see figure 2 In case electro catch is used jumper should be removed from joint J3 Figure 2 Selection of electro catch or electrom...

Страница 5: ...nt NbL 1 1 0 0 1 1 1 0 0 1 1 0 0 1 1 U H U H U H U H U H U U U U U H U H U H U H U H Sound signal of sign selected from the keyboard Multitone signaling of sign selected from the keyboard Duration of...

Страница 6: ...the apartment Addition of key with assigned to the apartment Addition of key on the selected item in memory Deleting the key Deleting the key assigned to the apartment Deleting the key recorded in the...

Страница 7: ...s configured as EC 2502 H after finishing of this operation the cassette will still operate in this mode Pushbutton RESET is used for momentary stopping the operation of a processor Its pressing makes...

Страница 8: ...nd supplier Subordinate entrances should be connected in such a way as if entry phone CD 2502 line L L was installed at the main entrance If CD 3100 is connected with CD 2501 mode with building number...

Страница 9: ...ne between cassette H and U KZ output of key switching on el catch if works as EC 2502H VZ electro catch supply L uniphone line if works as EC 2502U GZ mass of key switching on el catch LM master line...

Страница 10: ...n AC2 AC1 CP xxxx 12 V AC 1 A Brown Brown K6 K5 K4 K2 K3 K1 X GX GZ VZ KZ GZA VZA VP GP AC4 AC3 C C EC 2502 U 230 V AC 14 5 V AC 0 8 A White Brown AC2 AC1 CP xxxx 12 V AC 1 A AC4 AC3 Brown Brown L L K...

Страница 11: ...SY UTP LAN T11 XzTKMXpw Clamps Distance CP EC 15m 30m K1 K4 K1 K4 0 5mm 2x 0 5mm K2 K6 K2 K6 0 5mm 0 5mm K3 K3 3x 0 5mm 5x 0 5mm K5 K5 2x 0 5mm 2x 0 5mm X GX X GS 0 5mm 0 5mm Note In panels 250xxR GX...

Страница 12: ...nsiderably contributes to the protection of human health and life as well as protection of natural environment Return of packaging materials for the material recycling saves raw materials and reduces...

Отзывы: