![Laskomex CD-2000 Скачать руководство пользователя страница 24](http://html2.mh-extra.com/html/laskomex/cd-2000/cd-2000_installation-operation-and-programming-instructions_3786948024.webp)
- 23 -
CD-
Elementy systemu domofonowego
2500
Lock blocking
lock blocking is performed with the use of key with administrator authorizations. Its
application to the reader allows for lock blocking, having performed this operation
it is not possible to open the lock with user keys. Unblocking the lock takes place
after re-applying the administrator key to the reader.
Administrator key defining.
In order to program administrator key, one has to perform the following actions:
1. Enter the programming mode with the use of the MASTER key.
2. Press the door opening button or the button connected to terminals Z+, 4 for a
period of 5 s. The reader shall confirm its entry into administrator key programming
mode with acoustic signals one short and one long.
3. Apply the key which shall be awarded with administrator authorizations to the
reader.
4. It the key has been previously defined as the administrator key, it shall be removed
from the list of keys with this level of authorizations if it is not added to that list.
5. Press the door opening button again for a period of approx. 5 s.
6. Quit the programming mode (by applying the MASTER key to the reader)
Z1Z2 Electrocatch Electromagnetic lock Z1Z2V2V1 Z- Z+ 4 3X1JPLEDTM
GND
View from the elements side View from the print side Driver Configuration
7. Operation.
7.1. Control panel-to-uniphone call.
To call a desired flat, select its number touching digits forming the number. Each
correct touch is confirmed by both display of the selected digit and sound signal
from the cassette loudspeaker. After each touch 3üsecond time is counted. If the
next digit is touched within this time, the flat number is formed and displayed.
If a number greater then 999 is entered the entered number will be cancelled and
that digit which has caused overflow will be accepted as the first one. If no operation
on the keypad is made within 3 seconds, the displayed number will be considered
to be correct and the desired flat will be called.
If incorrect number is entered the display can be cancelled (by touching field C) and
correct number can be entered again. Prior to making connection with the selected
uniphone the system checks if the number has not been programmed as disconnected
from the system. If the selected number has
been disabled by means of suitable program, message OFF is displayed and sound
signal is heard.
When the connection is made ring signal is produced during 30 seconds (default
value). After the ring time further 30 seconds is allowed. During this time the
connection is maintained but the ring signal is not produced. Removal of the
handset from the cradle of the selected uniphone will result in talking connection
between the uniphone and the control panel.
Both ringing and wait can be interrupted at any moment touching the C field. In this
case the selected number disappears from the display and the system is ready for
acceptance of other number. When the uniphone handset is removed from the cradle
it is possible to have a talk. Its duration is limited to 2 minutes (default value). During
the talk the door catch can be unlocked
at any moment by depression of the uniphone pushbutton. Irrespective of the