5. Installing and connecting the video doorphone components
Installing and connecting the MVC-7002 monitor

For easier installation, all the wires of the video doorphone can be run to a standard
cable box installed in the wall. Once mounted, the monitor should cover the whole box.
This will make it easier to install and mount the monitor.
- The monitor is mounted on a metal holding bracket fixed to the wall. To fix the bracket,
place it against the wall in the intended place of installation and mark holes for rawl
plugs.
- Drill the holes as market and fix the bracket to the wall using rawl plugs.
- Connect the wires to the J102 socket connector provided with the kit, as shown in the
diagram, by soldering them to the wiring system. Protect all soldered connections and
isolated portions of the wires against short-circuit with a shrinking sleeve or insulating
tape. Plug the connectors to the sockets.
- Mount the monitor on the holding bracket.

Installing and connecting the additional monitor

For connecting two MVC-7002 monitors to a single outdoor panel, run a separate power
supply (J100 socket) to the additional monitor and connect the two monitors. See Figure
4, 5 and 6 (p. 7, 8)

Fig 7. Connectors in MVC-7002 monitor

9

Pin to J102 socket

(

optional - connection

additional external panel

)

Pin to J103 socket

(

optional - connection

additional external panel

)

Pin to J100 socket

(power supply)

red

+

black

-

red

audio

white

wideo

yellow

Vcc+

blue

masa

red

audio

white

wideo

yellow

Vcc+

blue

masa

Installing and connecting the BVC-6504 outdoor panel.

- Unscrew the screw holding the panel to the hood.
- Place the hood at the intended place of installation, mark holes for the rawl plugs and

drill the holes (Fig. 8b, p. 10). The camera lens should be placed at a height of approx.
150 cm (see Fig 8a, p. 10).

- Pull the wiring system cable through the circular hole in the casing and fasten the

casing to the wall (Fig. 8c, p. 10).

- Connect the wires according the diagram (see Fig. 5, p. 7). As shown in Fig. 5, the

LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ódŸ, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: [email protected], http://www.laskomex.com.pl

Содержание Bastion Apus II

Страница 1: ...Video door phone set Bastion Apus II...

Страница 2: ...installation of video door phone 6 Block diagrams 7 Connection diagrams 8 5 Assembly and connecting elements of video door phone 9 Assembly and connection MVC 7002 monitor 9 Connection a second monito...

Страница 3: ...fire The external panel should be installed in a place with low noise level Video door phone elements should be connected to an electrical installation when the feeder is disconnected from the power n...

Страница 4: ...access keyboard with a calling button The panel is surface mounted and equipped with a door strike relay activated on pressing the monitor button Fig 2 BVC 6504 outdoor panel 4 Fig 1 Monitor MVC 7002...

Страница 5: ...phone should only be used with door releases rated at 13 5V DC 1A max When choosing the door release take into account the mechanical design of the gate of the door it will be installed with and the o...

Страница 6: ...esented in Figure 7 The maximum distance between the external panel and the monitor should not exceed 100 m To put down in the ground and outside the room it is necesarry to use the damp proof cables...

Страница 7: ...KSAD 1350120W1EU KSAD 1350120W1EU KSAD 1500120W1EU or GP005E 150 100 b Description of clamps with connected electro catch 1 Push Down 2 Wires How to use clamps in external panel white WIDEO red AUDIO...

Страница 8: ...04 is changed KSAD 1350120W1EU Electro catch KSAD 1500120W1EU lub GP005E 150 100 230V AC 15V DC 1 2A 230V AC 13 5V DC 1 2A masa audio video audio video NO VDC za 12V za GND PRZ VDC Vcc 230V AC 15V DC...

Страница 9: ...g and connecting the additional monitor For connecting two MVC 7002 monitors to a single outdoor panel run a separate power supply J100 socket to the additional monitor and connect the two monitors Se...

Страница 10: ...tches on the camera view if an additional monitor has been installed the camera view will display on both monitors To switch on voice communication press the button talk see Fig 1 In two monitor insta...

Страница 11: ...2 enter your 4 digit administrator code you will hear 3 short sounds red LED is flashing you are now in programming mode 3 enter the location 01 to 40 31 40 are the latching code locations If a serie...

Страница 12: ...r 2 short sounds LED is flashing 5 press 7 times you will hear 5 short sounds LED is off Operation lock with code 1 enter your 4 digit user code 2 The red LED is lit this means user code is correct do...

Страница 13: ...ree of protection IP43 Angle of view vertical horizon 36 48 Power supply KSAD 1500120W1EU or GP005E 150 100 Input voltage 230V AC 230V AC Output voltage 15V DC 1 2A max 15V 1A Dimension 81x43x67 81x43...

Страница 14: ...Notes...

Страница 15: ...Notes...

Страница 16: ...List of collecting units of used Laskomex equipment is available on www laskomex com pl website or telephone No 42 671 88 68 Product packing should be removed according to environment protection regul...

Отзывы: