Manual / Bedienungsanleitung: RS 800 G, RS 800 RGY, RS 1000 RGB
Page / Seite 5 von / of 17
Revision Sep-10
OPERATING THE LASER
The operator has to make sure that laser radiation – also reflected laser radiation – higher
than the maximum permissible level is avoided by technical or organisational measures.
(Especially with respect to the MPE, see above.)
Make sure to use the correct voltage
If the device is used in a flying installation, the mounting brackets and an appropriate safety-
rope must be fixed.
In some countries, the operator must notify the accidence insurance and the authority for
industrial safety, before operating a laser. For more information, contact the relevant
authorities.
Please consider that unauthorized modifications on the device are strictly forbidden due to
safety reasons!
If this device will be operated in any way differently than described in this manual, the
product may suffer damages and the guarantee becomes void. Furthermore, any other
operation may lead to dangers like short-circuit, burns, electric shock, etc.
Keep surrounding dry and clean. T
his unit should be keep dry, do not use in the rain or
damp and dusty environment. Projector should be put in a water-proof housing when
operated outside.
Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog
fluid condenses in the housing (if so rearrange hazer and/or laser position).
Operating temperature is 10~35
°C
. In a new installation, check after some 15-30 minutes
whether the outlet air gets too warm. Regularly check the inside for dust deposits, especially
around the fans. Let laser cool off 10minutes after 2 hours of operation,to ensure maximum
lifetime for the diode.
Distance between laser aperture and projection screen should be not less than 1 meter.
Do not turn device on and immediately off again frequently.
Do not look into the laser beam directly, especially not with optical instruments.
Do not touch the device with wet hands.
When the laser diode becomes dim or broken, please contact your dealer timely.
When returning laser to dealer/manufacturer always use original packaging.
Maintenance should be performed every 15-day period. See “cleaning” further down.
Using the laser
Caution – use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation
exposure.
Make sure the correct voltage is used. Connect mains. Connect an emergency switch to the
9-pin conector on the backside (pins 1, 2). If you
do not wish to connect an emergency switch,
connect the 9-pin plug. Depending on the mode
selected (see below), laser light should come out
of the opening on the front panel – be careful.
1
Operation LED
2
Working LED: controlboard working
3
DMX LED: DMX connected
4
ILDA LED ILDA connected
5
DMX In/Out
6
Remotelock: connect emergency switch.
If no emergency switch is connected
use the 9 pin plug supplied.
7
Security switch: Laser on/off
8
ILDA connector in/out
9
Power switch: power on/off
10
Power: connect to mains