OPERATING THE LASER 

The operator has to make sure that laser radiation – also reflected laser radiation – higher 
than the maximum permissible level is avoided by technical or organisational measures. 
(Especially with respect to the MPE, see above.) 
Make sure to use the correct voltage 
If the device is used in a flying installation, the mounting brackets and an appropriate safety-
rope must be fixed. 
In some countries, the operator must notify the accidence insurance and the authority for 
industrial safety, before operating a laser. For more information, contact the relevant 
authorities. 
Please consider that unauthorized modifications on the device are strictly forbidden due to 
safety reasons! 
If this device will be operated in any way differently than described in this manual, the 
product may suffer damages and the guarantee becomes void. Furthermore, any other 
operation may lead to dangers like short-circuit, burns, electric shock, etc. 
Keep surrounding dry and clean. T

his unit should be keep dry, do not use in the rain or 

damp and dusty environment. Projector should be put in a water-proof housing when 
operated outside.  
Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog 
fluid condenses in the housing (if so rearrange hazer and/or laser position). 
Operating temperature is 10~35

°C

. In a new installation, check after some 15-30 minutes 

whether the outlet air gets too warm. Regularly check the inside for dust deposits, especially 
around the fans. Let laser cool off 10minutes after 2 hours of operation,to ensure maximum 
lifetime for the diode. 
Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer timely. 
When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. See “cleaning” further down. 

Using the laser 

Caution – use of controls or adjustments or performance of procedures 
other than those specified herein may result in hazardous radiation 
exposure. 

Make sure the correct voltage is used. Connect mains. Connect an emergency switch to the 
9-pin conector on the backside (pins 1, 2). If you 
do not wish to connect an emergency switch, 
connect the 9-pin plug. Depending on the mode 
selected (see below), laser light should come out 
of the opening on the front panel – be careful. 

Operation LED 

Working LED: controlboard working 

DMX LED: DMX connected 

ILDA LED ILDA connected 

DMX In/Out 

Remotelock: connect emergency switch. 
If no emergency switch is connected 
use the 9 pin plug supplied. 

Security switch: Laser on/off 

ILDA connector in/out 

Power switch: power on/off 

10 

Power: connect to mains 

Содержание RS 800 G

Страница 1: ...RS 800 G RS 800 RGY RS 1000 RGB Manual Read carefully before using this device Bedienungsanleitung Bitte lesen Sie diese Bedienungsanleitung bevor Sie das Ger t in Betrieb nehmen...

Страница 2: ...low Wichtig Beim Entfernen des Garantielabels erlischt sofort jeder Anspruch auf Gew hrleistung Wenn das Ger t grossen Temperaturschwankungen ausgesetzt war nicht sofort anschalten Gefahr der Kondensw...

Страница 3: ...ng 7 Technical specifications 7 Change scanner 7 Adjustable mirror mounts 8 Troubleshooting 8 ILDA signal 8 Please note 8 Hinweise zur Inbetriebnahme 10 Warnhinweise 10 Inbetriebnahme 11 Ger tekonfigu...

Страница 4: ...nto the light source as sensitive persons may suffer an epileptic shock These lasers are considered a definite eye hazard particularly at the higher power levels which WILL cause eye damage So these l...

Страница 5: ...ng temperature is 10 35 C In a new installation check after some 15 30 minutes whether the outlet air gets too warm Regularly check the inside for dust deposits especially around the fans Let laser co...

Страница 6: ...reduce the scanangle image size Otherwise you may damage the scanners When using with different scanspeed scanangle readjustment of the scanner drivers may be necessary if in doubt contact your dealer...

Страница 7: ...ffuse light can be seen inside the device When fog fluid condenses in the device clean all traces and rearrange the position of fazer and or laser Technical specifications Output power at the laser RS...

Страница 8: ...dark or dim Lenses mirrors dirty Clean with alcohol Laser diode defective Laser diode Inquire Control board defective Control board 26 2A LT12V2 00 Configuration wrong mode Check configuration see par...

Страница 9: ...on of 17 Revision Sep 10 Laserworld cannot be made liable for damages caused by incorrect installations and unskilled operation For service contact your dealer or Laserworld Only use Laserworld spare...

Страница 10: ...uchern Scheinwerfer Nebelmaschinen etc an derselben Leitung 6 Sorgen Sie immer f r eine ausreichende Bel ftung Insbesondere d rfen die Bel ftungs ffnungen nicht verdeckt sein 7 Netzstecker Kaltger teb...

Страница 11: ...riebnahme Verbinden Sie das Ger t mit dem Stromnetz Verbinden Sie einen Notausschalter oder den beigelegten Blindstecker mit der Interlock Anschluss an der R ckseite s u Schalten sie nun das Ger t mit...

Страница 12: ...g ber DMX Der Laser hat 14 Betriebskan le internationaler Standard DMX 512 Signal Kanal DMX512 Wert Funktion 1 Steuermodus 0 63 Automatischer Musikmodus Kanal 1 2 g ltig 64 127 Automodus Kanal 1 2 g l...

Страница 13: ...s Sie die Geschwindigkeit erh hen unbedingt die Bildgr e zun chst verringern sonst k nnen die Scanner zerst rt werden Eventuell ist bei anderer Geschwindigkeit eine Neujustierung der Scannertreiber er...

Страница 14: ...mkabel Schl sselschalter Interlock Adapter Anleitung Montagematerial Die Lieferung erfolgt im Flightcase Stromversorgung 220 240V AC 50 60 Hz oder 110 120V 50 60 Hz umschaltbar Stromaufnahme 120W Abme...

Страница 15: ...l s ubern Laserdiode defekt Bitte erfragen Steuerung PCB defekt Steuerung PCB 26 2A LT12V2 00 Ger tekonfiguration falsch berpr fen Sie die Konfiguration s Abschnitt Ger tebetrieb Keine Ansteuerung m g...

Страница 16: ...rld Ersatzteile Sollten nderungen an dieser Bedienungsanleitung vorgenommen werden k nnen wir Sie dar ber nicht in Kenntnis setzen Bitte kontaktieren Sie f r Fragen Ihren H ndler F r Service wenden Si...

Страница 17: ...il Oberhofen SWITZERLAND Authorized person Supervisory board Mr Martin Werner place of business 8574 Lengwil Oberhofen SWITZERLAND company number CH 440 3 020 548 6 Commercial Registry Kanton Thurgau...

Отзывы: