background image

User manual: RS-400G 

Rev: 09/2009 

Page 6 of 8 

1.

 

Loosen setscrews, then adjust with X/Y 
adjustable screws. Make sure beam is 
centered on scanner mirrors. 

2.

 

Adjust Z-screw simultaneously. 

3.

 

Tighten setscrews. 

4.

 

When combining beams (RGY/RGB laser), 
first make sure the beams are (roughly) on 
the same spot on the mirrors/dichros. Then 
use a test pattern (e.g. rectangle) to do fine 
adjustment. For adjustments, always turn 
output power down (if possible). 

Troubleshooting 

Problem 

Possible reason 

Damaged part 

Replacement 

Fuse blown 

Fuse 

09-00-3001-01 

No power 

Power supply defective 

+-24V 

16-03-0039-00 

Microphone defective 

Microphone 

16-03-0001-00 

Control board defective 

Control board 

26-2A-LT12V2-00 

Potentiometer defective 

Potentiometer 

04-03-0104-01 

Music mode not working 

CPU defective 

IC 

00-89C516RD-00 

Scanner defective 

Galvo 

15-01-2215-00 

CPU defective 

IC 

00-89C516RD-00 

 Control board defective 

Control PCB 

26-2A-LT12V2-00 

Power supply defective 

+-24V 

16-03-0039-00 

 

 

X and/or Y axis no 

deflection 

 

Scanner driver board defective 

Scanner driver board  

26-2A-6800A-00 

Lenses / mirrors dirty 

Clean with alcohol 

 

Laser diode defective 

Laser diode 

Inquire 

Control board defective 

Control board 

26-2A-LT12V2-00 

 
 

Laser dark or dim 

Configuration / wrong mode 

Check configuration (see 
paragraph control panel) 

 

Configuration / wrong mode 

Check configuration (see 
paragraph control panel) 

 

 Control board defective 

Control PCB 

26-2A-LT12V2-00 

Power supply defective 

+-24V 

16-03-0039-00 

Display board defective 

Display 

26-2A-YX2012DI-00 

 

 

 

No output 

Pins 4 and 17 of the ILDA signal 

not connected 

See below 

 

Laser does not switch to ILDA mode:  

 

The interface does not connect pins 4 and 17 of the IDLA signal. See interface manual 

 

The cable does not connect pins 4 and 17. Use a cable that connects pins 4 and 17. 

 

Use an adapter, that connects pins 4 and 17 (Interlock). 

ILDA signal 

Pin out of the standard ILDA signal: 

1 Scanner X+  

-10V..+10V 

14 X- 

+10V..-10V 

2 Scanner Y+  

-10V..+10V 

15 Y- 

+10V..-10V 

3 Intensity/B 

 0V..+2.5V 

16 Intensity/Blanking- 

0..-2.5V 

4 Interlock A 

 

17 Interlock B 

5 Red+  

0..2.5V 

18 Red- 

0..-2.5V 

6 Green+  

0..2.5V 

19 Green- 

0..-2.5V 

7 Blue+  

0..2.5V 

20 Blue- 

0..-2.5V 

8 – 12 Not used 

 

23-24 Not used 

13 S5V, max. 20 mA 

25 GND Signal ground

 

Содержание RS-400G

Страница 1: ...RS 400G User Manual Please read this manual carefully before use...

Страница 2: ...upervised by a skilled and well trained operator Never leave this device running unattended and keep it away from children and unauthorized persons Keep away from heaters and other heat sources In ord...

Страница 3: ...t in a water proof housing when operated outside Regularly open the device see cleaning further down to check for dust inside or if fog fluid condenses in the housing if so rearrange hazer and or lase...

Страница 4: ...canners are set to a scanspeed of ca 22000 PPS at ca 30 scanangle If you increase the scanspeed first reduce the scanangle image size Otherwise you may damage the scanners When using with different sc...

Страница 5: ...kes in one direction to minimize the effect of scratches Mirrors need cleaning when a halo is noticeable around the beam or an unusual high amount of diffuse light can be seen inside the device When f...

Страница 6: ...driver board defective Scanner driver board 26 2A 6800A 00 Lenses mirrors dirty Clean with alcohol Laser diode defective Laser diode Inquire Control board defective Control board 26 2A LT12V2 00 Lase...

Страница 7: ...lutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this...

Страница 8: ...tions DIN EN 60825 1 if properly set up according to the upper mentioned laser safety regulation After installing the device an inspection and official approval is indispensable for the overall setup...

Отзывы: