User manual: RS-400G
Rev: 09/2009
Page 5 of 8
0~63
No function
64~127
Extend horizontally
128~191
Extend vertically
9
Extend
192~255
Extend h. & v.
0~85
No function
86~169
Small to large
10
Zoom
170~255
Large to small
11
Drawing speed
0~255
slow to fast
12
Scan speed
0~255
slow to fast
13
Colour speed
0~255
slow to fast
0
Original size
14
Size
1~255
Small to large (120 = original)
Maintenace / cleaning
Always disconnect from mains before cleaning/opening the laser. You can open the device
by removing the top: remove the mounting bracket (4 quick locks), the 5 Philips screws, and
the eye bolt.
Regularly clean the interior from dust, especially ensure operation of the fans. To clean the
mirrors, ideally use acetone and lens cleaning paper (fold paper to get an edge with which to
clean the mirrors). If not available, you can also use window cleaner, and a paper towel. Be
careful, even light scratches reduce the output power of the laser; always clean with strokes
in one direction, to minimize the effect of scratches. Mirrors need cleaning, when a “halo” is
noticeable around the beam, or an unusual high amount of diffuse light can be seen inside
the device.
When fog fluid condenses in the device, clean all traces, and rearrange the position of hazer
and/or laser.
Technical specifications
•
Output power:
typical
:
400mW, guaranteed
:
300mW 532nm grün
•
Lasersources:
aircooled DPSS laser
•
Laser class:
3b
•
Modes:
ILDA, DMX 512, auto, music active
•
ILDA:
25pin ILDA standard Sub-D shaped 25pin connector
•
Galvos:
50k scanspeed
•
DMX 512:
14 channels
•
Patterns:
160
•
Scanangle:
set to ca. 40° optical (60° max)
•
Beam:
ca. 3mm/1mrad
•
Accessories:
power cable, key switch, interlock plug, manual, safety cord
•
The laser comes in a flightcase.
•
Input voltage:
AC 100~120V or 200~240V switchable 50/60Hz
•
Power consumption:
120W
•
Operating temperature:
10-35°C
•
Size:
550 x 320 x 310mm (W x D x H)
•
Weight:
15kg Laser,
total:
28kg
(with flightcase)
Change scanner
1.
Unscrew UK M6 screws and disconnect signal cable.
2.
Loosen M4 x 10 screw and remove galvo.
3.
Insert galvo, reconnect and fix signal cable.
4.
Rotate galvo to centre projection. Fix galvo.
Adjustable mirror mounts