8. Operation

1.  ILDA operation mode

The laser system is controlled over ILDA control signal. Plug in the ILDA cable to the ILDA-in 

interface at the unit.

2.  Scan Safety

This units has a special two-mode scan safety: It can be operated in scan fail safety mode, that 

prevents the occurance of dangerous radiation in case of malfunction. The beam block mode 

suppresses every too focussed beam to avoid the accidential exceeding of maximum permit-

ted exposure levels for spectators. The modes can be changed by using the switches at the 

control panel. The scan safety can also be switched off.

3.  Color blancing

By using the trim pots for color balancing it is possible to adjust the individual color sources to 

achieve a certain white balance. This is especially important if several laser systems are used 

an a homogenous white is needed.

4.  X/Y axis inversion

These switches invert the ILDA singal for the respective axis. This feature is useful if one ILDA 
signal line is used for controlling several lasers.

Содержание PL-20.000RGB CT

Страница 1: ...Manual PS 29 000RGB CT PL 20 000RGB CT PL 42 000RGB CT PL 20 000G CT Please read this manual carefully prior to product operation rev 10 2012 ns...

Страница 2: ...serworld AG cannot howe ver take any responsibility for errata bugs or the resulting damages The brands and product names mentioned in this manual are trade marks or registered trade marks of their re...

Страница 3: ...y acces sible 8 When installing the laser mount it with a minimum distance of 15 cm from walls and objects 9 For safe setup e g on walls or ceilings please use a safety cord The safety cord should be...

Страница 4: ...goggles gloves etc accor ding to laser power and wavelength of the laser 5 Service notes Moisture and heat can reduce lifetime of the laser system dramatically and expires any warranty claim Quick on...

Страница 5: ...ther notices on the device Laser radiation Avoid exposure to beam Laser class 4 Caution of radiation if cover is removed power supply consumption model type wavelength Output power production year Ple...

Страница 6: ...cussed beam to avoid the accidential exceeding of maximum permit ted exposure levels for spectators The modes can be changed by using the switches at the control panel The scan safety can also be swit...

Страница 7: ...our dealer For service please contact your dealer or Laserworld Please use only spare parts of Laserworld Subject to change without notice Because of the vast amount of data we cannot guarantee any co...

Страница 8: ...m 2mrad full angle divergence PL 20 000G CT ca 5 5mm 2mrad full angle divergence Power supply 230V 50Hz 5 Power consumption max 600W Operating temperature 10 to 35 C Dimensions 510 x 390 x 290 mm L x...

Отзывы: